EVRM-NA 

Safety solenoid valves for gas 

Manual reset - Normally open 

 

 
 

The EVRM-NA type valve is a manual reset safety valve 
that is normally open.

 

This type of device, connected 

with one or more gas leakage detectors or alarm signals 
for the presence of carbon monoxide, is suitable for 
performing  locking operations on the gas line. 

The EVRM-NA type valves are made in accordance with 
EN161 standard (when applicable). All models are 
conforming with the European Directives 89/336 EEC 
and 73/23 EEC. 

 

1- Features 

 

‰

 

Wide range for inlet/outlet connections, from 3/8” to 
8” pipes sizing. 

‰

 

Provided with G1/4” pressure gauge on two sides in 
the inlet pressure chamber (except brass models). 
Others gauge points on request. 

‰

 

Optional G1/8” connection for closed position 
indicator micro switch (on request from 3/4" to 8"). 

‰

 

Fine mesh filter incorporated to prevent dirty 
contamination of the seal seat (except brass 
models). 

‰

 

Maximum operating pressure 500 mbar. 

‰

 

Suitable for air and non-aggressive gases (EN 437, 
1, 2 and 3 families). 

‰

 

Coil insulation is class H (180°C). 

‰

 

Terminals with DIN 43650 plug and PG connector. 

‰

 

Valves are 100% tested by computerized testing 
machineries and are fully warranted. 

‰

 

For valve identification see the following charts. 

 
 
 

WARNING 

This control must be installed in compliance with 
the laws in force. 

Read instructions before use. 

Elettromeccanica Delta S.p.a. reserves the right 
to update or make technical changes without 
prior notice.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 1 

 

2- Technical specifications 

 

Connections ………………..

 Gas threaded ISO 7/1 

 

from Rp3/8 to Rp2 

 

Flanged PN16 – ISO 7005 

 

from DN40 to DN200 

Voltage  rating ……………...

 230 VAC 50/60 Hz 

Voltages on request

 ………. 110 VAC 50/60 Hz 

 

24 V AC/DC 

 

12 VDC  

Voltage tolerance ………….

 -15% / +10% 

Power consumption ……….

 see charts 

Environment temperature …

 -15°C / +60°C 

Max. working pressure ……

 500 mbar  

Flow capacity ………………

 see charts 

Disc sealing …..…………… 

NBR  

Closing time ………………..

 < 1 sec. 

Protection class ……………

 IP 54 (EN60529) 

Cable gland …………………

PG09  

Overall dimensions ………..

 see charts

 

 
 
 

Содержание EVRM-NA Series

Страница 1: ...Printed in Italy EE167 0105 EVRM NA Safety solenoid valves for gas Manual reset Normally open DN10 DN200 EVRM NA6 EVRM NA9 Certified Quality System www elektrogas com ...

Страница 2: ...vent dirty contamination of the seal seat except brass models Maximum operating pressure 500 mbar Suitable for air and non aggressive gases EN 437 1 2 and 3 families Coil insulation is class H 180 C Terminals with DIN 43650 plug and PG connector Valves are 100 tested by computerized testing machineries and are fully warranted For valve identification see the following charts WARNING This control m...

Страница 3: ...min max adjustable pressure switches leakage tester or other gas equipments Flanged models are provided with gauges in the outlet chamber too Brass models are available without gauges only On request valves are supplied with a G1 8 connection on the bottom to installed a closed position indicator micro switch from 3 4 to 8 An adapting rod is provided too 5 Coil features Coil and DIN plug are provi...

Страница 4: ...MNA7D DN 80 EVRMNA8A EVRMNA8B EVRMNA8C EVRMNA8D DN 100 EVRMNA9A EVRMNA9B EVRMNA9C EVRMNA9D DN 125 EVRMNA93A EVRMNA93B EVRMNA93C EVRMNA93D DN 150 EVRMNA95A EVRMN95B EVRMNA95C EVRMNA95D DN 200 EVRMNA98A EVRMN98B EVRMNA98C EVRMNA98D Fig 3 Connections Overall dimensions mm Model Threaded Flanged Max Pressure mbar Power Consump 230VAC W A B C D Int h Weight Kg EVRMNA0 O Rp 3 8 500 16 30 58 115 130 0 4 ...

Страница 5: ...tural gas Town gas Air V m h 1 3 4 OT 3 8 OT 1 2 OT 1 OT 1 2 3 8 3 4 1 2 1 DN 200 Liquid gas 8 Loss of pressure Formula of conversion from air to other gases 15 C 1013 mbar dry Gas type Specific gravity Kg m K Air 1 25 1 00 Natural Gas 0 80 1 25 Town Gas 0 57 1 48 Liquid Gas 2 08 0 77 ...

Страница 6: ... 225 85 Rp1 340 125 Rp1 475 160 Rp1 DN40 610 200 50 Rp2 DN50 1100 250 50 DN65 1600 50 DN80 2400 50 DN100 5000 80 DN125 6000 160 DN150 7600 160 DN200 7600 160 Fig 4 Valve may be mounted with coil in horizontal or vertical position Coil may be oriented 360 degrees in any direction 10 Electrical connections IEC 730 1 Check correspondence between valve voltage rating and line power supply before makin...

Страница 7: ... Do not use tools because a lip damage could result 10 Remove the filter and blow it with compressed air 11 Reassemble the valve following the inverse sequence Flanged models 1 Close ball valve upstream the system 2 Unscrew the knob 3 Using an Allen key remove the screws on the upper flange in cross way The gas in the valve will come out during this step 4 Check the main O ring and the rod O ring ...

Отзывы: