3.4.3.3 Menu “Reset Device”
Entering this menu item will prompt for acknowledgement to reset the device completely to default settings and
set values. Selection “
No
” will cancel the reset procedure, while selection “
Yes
”, submitted by
button, will
instantly reset the device.
3.4.3.4
Menu “Profiles”
See
„3.8 Loading and saving a user profile“ on page 57
.
3.4.3.5 Menu “Overview” and “About HW, SW,...”
This menu pages display an overview of the set values (U, I, P) and related protection settings (OVP, OCP, OPP)
as well as limits settings and an alarm history (counter) of alarms that might have occured since the last time the
unit was switched on. Furthermore they show device relevant data such as serial number, article number etc.
3.4.3.6 Menu “Communication”
Here settings for the Ethernet port (on rear side of device) are made. The USB port there doesn’t require any settings.
When delivered or after a complete reset, the Ethernet port has following
default settings
assigned:
•
DHCP: off
•
IP: 192.168.0.2
•
Subnet mask: 255.255.255.0
•
Gateway: 192.168.0.1
•
Port: 5025
•
DNS: 0.0.0.0
•
Host name: Client
•
Domain: Workgroup
Those settings can be changed anytime at will, in the setup menu or via the device website, which you can open
from the current IP or host name (also see
Submenu “
IP Settings 1
”
Element
Description
Get IP address Manual
(default): uses the default (after delivery or reset) or the last set network parameters.
Those parameters are not overwritten by selection “
DHCP
” and remain when switching back
from “
DHCP
” to “
Manual
”
DHCP
: after switching to DHCP and submitting the change with button
, the device will
instantly try to get network parameters (IP, subnet mask, gateway, DNS) assigned from a DHCP
server. If the attempt fails, the device will use the settings from “
Manual
” again. In this case, the
overview in screen “
View settings
” will indicate the DCHP status as “
DHCP (failed)
”, otherwise
as “
DHCP(active)
”
IP address
Only available with setting “
Get IP address = Manual
”. Default value: 192.168.0.2
Permanent manual setting of the device’s IP address in standard IP format
Subnet mask
Only available with setting “
Get IP address = Manual
”. Default value: 255.255.255.0
Permanent manual setting of the subnet mask in standard IP format
Gateway
Only available with setting “
Get IP address = Manual
”. Default value: 192.168.0.1
Permanent manual setting of the gateway address in standard IP format
Submenu “
IP Settings 2
”
Element
Description
Port
Default value: 5025
Adjust the socket port here, which belongs to the IP adress and serves for TCP/P access when
controlling the device remotely via Ethernet
DNS address
Default value: 0.0.0.0
Permanent manual setting of the network address of a domain name server (short: DNS) which
has to be present in order to translate the host name to the device’s IP, so the device could
alternatively access by the host name
Enable TCP
keep-alive
Default setting: No
Activates/deactivates the so-called “keep-alive” functionality of Ethernet connections