Handling the device
Pin assignment and technical specifications of the analogue interface:
Pin
Name
Type
1
Description
Level
Electrical specifications
1
VSEL
AI Set value: Voltage
0….10V correspond to 0….100% of U
nom
2
CSEL
AI Set value: Current
0….10V correspond to 0….100% of I
nom
VREF
AO Reference voltage
10V
Accuracy <0.5% at I
max
= 5mA
4
VMON
AO Actual value: current
0….10V correspond to 0….100% of U
nom
5
CMON
AO Actual value: voltage
0….10V correspond to 0….100% of I
nom
6
AGND
Reference for analogue signals
For CMON, VMON
7
Remote
DI Activate external control
External = Low (U
low
<1V),
Internal = High (U
high
>4V)
8
Rem-SB
DI Power output off
Off = Low (U
low
<1V),
On = High (U
high
>4V)
9
OT / OVP
DO Overtemperature OT /
Overvoltage OVP
Low = No error (U
low
<1V)
High = Error (U
high
>4V)
U
max
= 0V, I
max
= 20mA
Quasi Open Collector with
pull-up to +15V
10
DGND
Reference for digital signals
For control and monitoring signals
11
Reserved
X
must not be connected
12
Reserved
X
must not be connected
1)
AO = Analogue output, DI = digital input, DO = digital output
Accuracy 0.2% at I
max
= +2mA
Short-circuit-proof against AGND
U
max
= 0V
Imax = -1mA at 5V
Accuracy <0.5%, U
max
= 12V
Input impedance >100k
The analogue monitoring outputs put out 0...10V which
corresponds to 0...100% of the nominal values.
Reference is analogue ground (AGND).
Set values 1
Analogue inputs (AI)
The example shows how the set values can be con-
trolled using the reference voltage (10V, VREF) and
potentiometers on the set value inputs.
The potentiometer should be 10kOhm each or hig-
her.
Set values 2
Analogue inputs (AI)
The example shows how to control voltage and cur-
rent by means of external voltage sources.
Attention! Never connect voltages >12V to these
inputs!
Set values >10V are clipped to 100% nominal va-
lue.