![elektraLite lightStream Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/elektralite/lightstream/lightstream_user-manual_2386572008.webp)
6. Channel Values for profiling the Elektralite lightStream (Cont).
Channel name
Function
Min
DMX
Value
Max
DMX
Value
St Ex Ba
8bit
Ba
16bit
16 19 15 18 LED
5
Also
known as
(Color E)
Black out
000
003
Going through the colors from red
→
green
→
blue
→
white 004
243
Red 244
245
Green 246
247
Blue 248
249
White 250
251
Blended white using all colors
252
255
17 20 16 19 LED
6
Also
known as
(Color F)
Black out
000
003
Going through the colors from red
→
green
→
blue
→
white 004
243
Red 244
245
Green 246
247
Blue 248
249
White 250
251
Blended white using all colors
252
255
18 21 17 20 Control
Normal
000
007
Reset All See below
008
015
Pan & Tilt Reset See below
016
023
Not used
024
031
Not used
032
039
Not used
040
047
Not used
048
055
Display Off
056
063
Display On
064
071
Not used
072
079
Not used
080
087
Hibernation (see menu section 7 for explanation of hibernation)
088
095
Not used
096
255
There is a choice of 4 modes that the
ElektraLite lightStream
can operate
.
The default channel configuration out of the box, is Standard Mode
(St)
using a total of 18 channels of DMX.
Extended mode
(Ex)
uses 21 channels.
Basic 8bit mode
(Ba 8bit)
uses 17 channels.
Basic 16bit mode (
Ba 16bit)
uses 20 channels.
Reset
Holding the dmx output at the level required will start a reset. However if the output is kept at this level and not returned to some
other value outside the dmx range for the reset, then the fixture will constantly do resets! So, once the reset starts take the channel
output to 000.