ELEKTRA VCDR
Heating Cables
Downpipes
Single-led heating cables – do not require fixing if
the length of the heated downpipe does not exceed
6 m.
Double-led heating cables – to be fixed with holders
(holder spacing should not exceed 40 cm) or a wire
with clips. Wire with clips are applied when the
length of the heated downpipe exceeds 6 m.
Downpipe spacing clip
Downpipe spacing wire with clips
Leading the cables
in gutters and downpipes