• ELEKTRA SelfTec PRO
heating cables should be
mounted on the pipeline
with fiberglass
installation tape fixed
every 30 cm.
• For plastic pipelines,
fix additionally AL tape
along the heating cable.
This will improve
the temperature
distribution on the surface
of the pipeline.
• Heating cables should be mounted along the heated pipeline in the
bottom part of its cross-section. Temperature controller should be placed
on the pipe under insulation, max. away from the cable.
• After the installation of the heating cable and sensor has been completed,
thermal insulation should be placed on the pipeline.
22
Installation Manual
Self-regulating Heating Cables
®
ELEKTRA SelfTec PRO