Primary heating
When selecting the heating cable,
it is necessary to consider:
• The heat demands of the room (necessary to
cover the heat losses and maintain the required
temperature level).
• The fixed-furniture-free floor area, where the
heating cable can be laid.
• The heating cables should be laid at the
maximum distance of 10 cm from one another,
so that the underheated or cold spots do not
occur.
• The heating cables should be laid at a minimum
distance of 4 cm from one another for the
UltraTec cable or 5 cm for the DM cable,
for ceramic tile finishing.
• The distance between the heating cables
for wooden floors, Vinyl or fitted carpet
should be 10 cm.