15
Failure to Power OFF the Control Unit during the wiring
process could result in damage to the ElectroStrainer System.
Location and Mounting
1.
Mount the ElectroStrainer Control Unit (1) on a bulkhead in the engine room using four
#10 stainless steel Mounting Screws provided. The Control Unit is designed for marine
engine rooms with a maximum environmental temperature of 50
°
C (122
°
F). Do not
mount Control Unit in an area that receives excessive heat.
Control Unit to 12 or 24VDC Power Supply
2.
Power OFF the Control Unit (2) before beginning the wiring process below. Locate an
always on, 12 or 24VDC power source on the vessel. Connect the
RED (+)
and
YELLOW (-)
wires of the Power Cable to this source according to the appropriate electrical standards
(i.e. ABYC). Connect the Power Cable (A) to the Control Unit.
Control Unit to Canister
•
Connect the Cell cable (B) between the Control Unit and the Canister
Control Unit to ClearVis Flow Sensor
•
Connect the Flow Sensor cable (C) to the Control Unit and the Flow Sensor.
Canister Bonding
•
Connect vessel bonding wire to Canister bonding terminal according to appropriate
bonding standards (i.e. ABYC).
U.S. Patent No. 11,027,991 and other U.S. and Foreign Patents Pending
NOTICE
ElectroStrainer Control Unit Installation
15
Control Unit Mounting and Wiring
NOTICE
B
A
2
A
B
Canister Assembly
Sample Vessel
12 or 24VDC Source
1
C
C
Bonding
Terminal
Failure to bond ElectroStrainer will void Warranty.