Note: During the registration procedure, make certain that no other wireless devices are transmitting so as not to
interfere with the registration procedure. In the event that the wrong transmitter is registered to the receiver, you can
delete the transmitter as explained on the following page – see Deleting the Registered Transmitter.
To perform an External Siren Test:
•
From the Service menu, select Ext. Siren Test [72].
When the first transmission is received, the Registration LED on the receiver switches off. After the second
transmission is received, the LED flashes. When the LED stops flashing, the registration procedure is complete.
8.
Before permanently mounting the INF-WSM, test the reception from the exact mounting position. If
necessary, relocate the receiver to a better position.
9.
Via the wiring hole on the back cover, connect a 13.8VDC regulated AC/DC adapter to the DC jack on the
INF-WSM –
do not apply power yet!
10.
To mount the INF-WSM, place the metal housing in position against the wall and mark the upper and lower
mounting holes. Install wall anchors in the appropriate positions and mount the metal housing using four
screws.
11.
Replace the front cover and secure with the cover screws.
12.
Apply mains power by connecting the adapter to an AC outlet.
Wiring the Unit
The INF-WSM is able to interface with most popular sounders. To connect the INF-WSM to a sounder, refer to the
following wiring reference table and Figure 4 below.
Infinite-WSM S
T – +
Lynteck Vortex
STB- TG- HOLD
-
HOLD+
Ventcroft Classic
NT
STB-
TRG
HOLD OFF -
HOLD OFF +
C&K AG6
ST- SW- V- V+
CQR Security Sigma
STRB
BELL
HOLD OFF -
HOLD OFF +
Texecom Odyssey
S (STRB)
B (BELL)
D (0V)
A (12V)
Texecom Azura 360
S (STRB)
B (BELL)
D (0V)
A (12V)
Texecom Tempest
S (STRB)
B (BELL)
D (0V)
A (12V)
Elmdene Sounda
-ST -R -H +H
Micotech Flashguard
STROBE -
TRIGGER -
SUPPLY -
Pyronix Belle
STB BA B- B+
Strobe Current Economy
Strobe Current Economy is a feature that is designed to conserve the backup battery. If this feature is enabled, the
strobe operates in “siren follower” mode when mains power is disconnected. This means that the strobe will only
function when the siren trigger is on.
•
To enable the Strobe Current Economy feature, install the SCE jumper
– see Figure 2
.
•
To disable the Strobe Current Economy feature, remove the SCE jumper and place over one pin for
storage.
Deleting the Registered Transmitter
In certain cases, it may be necessary to delete the registered transmitter in order to allow the registration of a new
transmitter. To delete a registered transmitter:
1.
Press and hold down the Registration button; the Registration LED is lit.
2.
Continue to hold down the Registration button until the Registration LED turns off; the registered transmitter is
deleted.
Technical Specifications
Operating Voltage: 13.8VDC (regulated)
Backup Battery: 12V/0.8Ah
Receiver Frequency: 868.35, 433.92 or 418MHz FM
Current Consumption: 25mA
Dimensions: 163 x 133 x 41mm