background image

ABMHZ Version 1+1 

Advanced User Manual

 

20 November 2007     Rev. B 

©2007, Electronic Solutions, Inc. 

page 1 of 5 

1355 Horizon Avenue, Lafayette, CO  80026-9304  USA 

voice: +1.303.469.9322    fax: +1.303.469.5129   www.elec-solutions.com 

Electronic

Solutions, Inc.

1.

 

Introduction 

This document is for the advanced user who has knowledge of the Z-Wave™ 
Command Classes and is able to initiate Z-Wave commands programmatically. 
 
When the ABMHZ sends a Node Info Report, it reports itself as a Basic Slave 
device with generic support for Multilevel switch, specifically supporting the Multi-
position motor class.  In addition to the mandatory command classes, it also 
supports Manufacturer Specific, Version, All Switch, Configuration, and Power level 
command classes (details and examples on how to utilize these classes below). 

2.

 

Status LED  

On power-up, LED blinks GREEN once indicating Z-Wave processor Version 1. 
This LED will blink green on reception of a valid Z-Wave command. 
This LED will blink red if an error has occurred. 

3.

 

Motor LED  

On power-up, this LED will blink RED once indicating motor processor Version 1. 
This LED will stay red after power-up if the unit is not calibrated. 
This LED will be green when ready for calibration (please see Calibration section). 

4.

 

COMMAND_CLASS_CONFIGURATION Commands 

There are 3 configuration parameters accessible via the  
COMMAND_CLASS_CONFIGURATION.  Each parameter is a single byte, and can 
only contain the value of 1 or 0. 
 

Sample commands: 

 
To check unit calibration state, send CONFIGURATION_GET, 1.  Return is a 0 or 1. 
To check unit motor direction state, send CONFIGURATION_GET, 2.  Return is a 0 
or 1. 
To check unit tilt feature state, send CONFIGURATION_GET, 3.  Return is a 0 or 1. 
 
To initiate calibration sequence, send CONFIGURATION_SET, 1, 1, 1.  
To set motor direction to reversed and calibrate, send CONFIGURATION_SET, 2, 1, 
1 (if already reversed, then no action). 
To return all settings to factory default, send CONFIGURATION_SET, 1, 129, 1. 
 
 

Содержание ABMHZ

Страница 1: ...sor Version 1 This LED will blink green on reception of a valid Z Wave command This LED will blink red if an error has occurred 3 Motor LED On power up this LED will blink RED once indicating motor processor Version 1 This LED will stay red after power up if the unit is not calibrated This LED will be green when ready for calibration please see Calibration section 4 COMMAND_CLASS_CONFIGURATION Com...

Страница 2: ...a 0 or 1 Return to factory defaults Unit uncalibrated motor direction normal tilt disabled 5 COMMAND_CLASS_BASIC Commands A BASIC_GET will return a motor position value between 0 and 99 or 255 A value of 255 means the motor is not calibrated and cannot report a valid position The Motor LED will also be red A BASIC_SET 0 will move the shade of a properly calibrated motor to the fully closed positio...

Страница 3: ...WITCH_START_LEVEL_CHANGE with parameter 1 bit 6 set causes the position value to decrease and the shade closes regardless of the calibration status The values of the Ignore Start Level bit parameter 1 bit 5 and the Start Level parameter parameter 2 are ignored However for compatibility with other Z Wave devices the Ignore Start Level bit should be set to 1 Sending a MULTILEVEL_SWITCH_STOP_LEVEL_CH...

Страница 4: ...cknowledged It is also possible to query for the results of the last test by sending a POWERLEVEL_TEST_NODE_GET Send POWERLEVEL_SET 5 60 to set node to power level 5 mid level power for 60 seconds 9 COMMAND_CLASS_MANUFACTURER_SPECIFIC Command Send MANUFACTURER_SPECIFIC_GET The return message should be 0x00 0x33 0x52 0x50 0x30 0x31 This shows the ESI product data as Manufacturer ID 0033 Product Typ...

Страница 5: ...d CLOSE buttons simultaneously for approximately 10 seconds until the Motor LED turns green While the Motor LED is green within 10 seconds Press the CLOSE button to start a calibration sequence or Press the OPEN button to reverse the motor direction and start a calibration sequence A calibration sequence consists of the shade moving between the upper and lower limits and stopping at the fully clos...