PosiTector

6000

INSTRUCTION MANUAL v. 

6.0

/M

for Memory (3) models

Coating Thickness Gages

Separate
probe

Built-in
probe

ELECTROMATIC 

E   Q   U   I   P   M   E   N   T     C   O .,

I   N   C .

600 Oakland Ave., Cedarhurst, NY 11516–U.S.A.
T E L : 5 1 6 - 2 9 5 - 4 3 0 0  

•  

FA X : 5 1 6 - 2 9 5 - 4 3 9 9  

Содержание PosiTector 6000

Страница 1: ...INSTRUCTION MANUAL v 6 0 M for Memory 3 models Coating Thickness Gages Separate probe Built in probe ELECTROMATIC E Q U I P M E N T C O I N C 600 Oakland Ave Cedarhurst NY 11516 U S A TEL 516 295 4300 FAX 516 295 4399 ...

Страница 2: ...combine the full abilities of both the F and N probes Certification All probes or gages are shipped with a Certificate of Calibration For organizations with re certification requirements gages may be returned at regular intervals for calibration DeFelsko recommends that customers establish gage calibration intervals based upon their own experience and work environment Based on our product knowledg...

Страница 3: ...en and the measurement is displayed 4 Lift probe AT LEAST 2 INCHES 5cm from the surface between measurements OR leave probe on the surface in the same location for continuous measurements every 2 seconds Do not drag the probe sideways across the surface Golden Rule Golden Rule Measure your uncoated part first This quick zero check determines if a calibration adjustment is need ed for your substrat...

Страница 4: ...h buttons at any time to exit any menu or select Exit from the Menu When there are more menu options than can fit onto one screen a scroll bar will appear The dark area indicates what portion of the total menu you are currently viewing List boxes have a down arrow on the right hand side Use the and buttons until your desired choice appears then press to select this choice and move focus onto the n...

Страница 5: ...Verification Verification is an accuracy check performed by the user using known reference standards A successful verification requires the Gage to read within the combined accuracy of the Gage and the reference standards Adjustment Adjustment or Calibration Adjustment is the act of aligning the Gage s thickness readings to match that of a known sample in order to improve the effectiveness of the ...

Страница 6: ...ed at any time by performing a Reset pg 15 creating a NEW calibration setting pg 9 or by DELETING the adjustments made to the Cal 1 calibration setting pg 10 The symbol appears on the display whenever factory calibration settings are in use With FN Gages calibration adjustments are made only to the F or N mode stored independently under a particular Cal whichever was measured last Once adjusted yo...

Страница 7: ... probe on the surface After the last measurement the Gage will calculate and display 0 which represents the average of all the Zero readings taken 3 Simple Adjustment to a Known Thickness It is sometimes desirable to adjust the Gage to a known thickness such as a shim rather than adjusting it to zero Measure the object If the expected reading is not obtained within tolerance lift the probe from th...

Страница 8: ...ate materials shapes or conditions Provides greater accuracy within a limited defined range This method requires taking two readings at known thickness values a thin value often zero and a thicker value These values should be on either side of the thickness range to be measured 1 Select 2 Pt Adjust from the Cal Settings menu 2 Press to select the number of readings to be used to obtain an average ...

Страница 9: ...ownload special Cal settings Calibration Memory Calibration Memory It is often convenient to retain a particular calibration adjustment before making another Then if you return to that part the corresponding calibration setting can be restored A setting is any calibration adjustment The PosiTector 6000 always displays the currentcalibra tionsetting ex Cal 3 in the upper right corner of the display...

Страница 10: ...Settings to either the IR printer using the Gage s built in IR port or to a PC s default printer using the included USB cable 10 loads an existing setting Use the buttons to scroll the List box until the desired setting appears then press A warning message will prevent the opening of a stored Cal setting if a batch is open and has readings Create a new batch first or open a batch containing no rea...

Страница 11: ... and basic statistics are displayed Each measurement will now be simultaneously shown on the display and stored into this new batch On screen statistics are immediately updated with each measurement New batch names are date stamped at the time they are created When a batch is open create a new batch by pressing creates a new sub batch In this example B2s2 is a sub batch of Batch 2 Sub batching all...

Страница 12: ...tics from the display removes a batch or sub batch completely from memory The name is deleted and all measurements are erased Sub batches can be deleted individually To delete all related sub batches simply delete the top level batch lists all readings onto the display from the current or most recently used batch or sub batch It begins by showing the last 10 measurement values Scroll using the or ...

Страница 13: ...ions prints histograms and basic charts manages data and readings can be exported to a document or spreadsheet 13 outputs a statistical summary to the optional IR printer using the built in IR port or to a PC s default printer using the included USB cable Individual measurements with their time stamp are printed if the Readings box is ticked A histogram is printed if the Graph box is ticked HiLo c...

Страница 14: ...red value and make final adjustments with the buttons Select NEXT to accept this value The current Hi setting is now displayed Follow the same procedure to adjust this setting The icon will appear on the display Measurements will now be compared to your defined limits The Gage beeps and blinks green twice if results are within those limits A single low tone will display if it is below the Lo limit...

Страница 15: ...cleared and returned to the Gage s factory calibration settings Cal 1 this symbol appears on the display It disappears if a calibration adjustment is made by the user menu settings are returned to the following Hi Res OFF Cal Lock OFF Statistics OFF Hi Lo Alarm OFF N Lock OFF FN models only A more thorough Reset can be performed when the Gage is powered down by holding the button until the Reset s...

Страница 16: ...onverts the display and all stored readings from inch to metric or vice versa All batches are date stamped when created and all measurements are time stamped 24 hour format when stored into these batches It is therefore impor tant to keep both the date and time current using this menu button Alternatively the date and time can be automatically updated when the gage is connected to PosiSoft using t...

Страница 17: ...moved from the vicinity of metal and power down after 3 minutes of no activity The continuous measurement feature is only intended to allow careful probe placement on small or odd shaped surfaces Simply ignore all readings taken before the probe is properly placed Do not drag the probe sideways Standard probes These constant pressure stainless steel probes are hermetically sealed to be totally wat...

Страница 18: ... measured with the PosiPen B It is ideally suited for measuring on small hot or hard to reach surfaces automatically attempts a measurement using the eddy current principle If the coating is non conductive over metal a reading is displayed with the letter N Non Ferrous Lock Option appears on FN Combination models only Select N Lock when operating regularly on non ferrous substrates The probe will ...

Страница 19: ...x number or email address T Troubleshooting roubleshooting Some common reports received by our Service Department along with possible causes are located on our website Most conditions however can be cleared with a Reset pg 15 Nickel cadmium and nickel metal hydride recharge able batteries will work but the Gage may appear to have weak batteries To retain all user settings and stored memory read in...

Страница 20: ...returned instrument is defective as to workmanship or material the instrument will be repaired or replaced at DeFelsko s sole option In no event shall DeFelsko be liable for any indirect special incidental or consequential damages The warranty is voided if the Instrument has been opened Data subject to change without notice T Technical Dat echnical Data a Gage body dimensions 5 75 x 2 5 x 1 2 146 ...