TSE-P 01.01 EB
43/56
599 34 55-61
READING THE LAST ALARM CONDITION
The diagnostics system makes it possible to identify the last alarm condition which occurred during the
operation of the appliance.
to read this alarm condition, after accessing the diagnostics system (see "Access to the diagnostics /
configuration system),
turn the programme selector knob two positions counter-clockwise
from the
RESET position.
The alarm condition is displayed; the corresponding binary code flashes on the wash phase LEDs (and on
the display).
the first four LEDs indicate the first digit of the alarm code
the second four LEDs indicate the second digit of the alarm code
For example, if an
E41
alarm condition (door open) is generated, the display will show
E41
and, at the same
time, the second LED in group
A
(equivalent to
4
in binary code) and the fourth LED (equivalent to
1
in
binary code) will also flash.
If no alarm conditions have occurred, the display shows
E00
.
DIAGNOSTICS CYCLE ALARMS
If a malfunction should occur during the course of the diagnostics cycle, the relative alarm codes are
displayed. In this case, too, the wash phase LEDs (and the display) show the error code (flashing).
BINARY CODES
The table below shows how to convert the binary code displayed by the LEDs into the corresponding
decimal number.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
A
b
C
d
E
F
LED OFF
LED LIT