![Electrolux W555H Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/electrolux/w555h/w555h_installation-manual_93079012.webp)
12
Installation manual
Thread the holes with M10 bolts.
Thread up the four feet of the machine as much as possible.
Place the machine at its site.
Place the spacers (B) between the machine and the floor.
Tighten the machine to the floor with the two bolts.
Adjust the feet of the machine to the floor and lock them with the nuts.
fig.2521A
5 Water connection
All water intake connections to the machine should be fitted with manual shut-off valves and filters, to facilitate instal-
lation and servicing.
Water pipes and hoses should be flushed clean before installation.
The machine shall be connected with new water hoses. Re-used water hoses must not be used.
Hoses are to be of an approved type and grade and comply with IEC 61770.
After installation hoses must hang in gentle arcs.
The machine can have one or two supply hoses.
Machine with cold water intake only.
Machine with hot and cold water intake.
When the machine is prepared for cold and hot water but no hot water
is available, both valves must be connected with cold water.
Water pressure:
Miniumum: 50 kPa (0.5 kp/cm
2
)
Maximum: 1 MPa (10 kp/cm
2
)
Recommended: 200-500 kPa (2–5 kp/cm
2
)
For WRAS-approved machines; always check connection requirements on WRAS website.