F.3
Accessing the appliance’s internal
components
G
INSTALLATION AND ASSEMBLY
G.1
Appliance type
When describing our appliances, we distinguish between top
modules
A
, base modules
B
and factory-assembled units
C
.
Top and base modules can be set up together or as individual
units.
The appliance must always be installed in its intended location
according to the relevant installation and connection diagrams
(F
). The appliance should be con-
nected to fixed cables.
Installation options:
1.
Wall mounted
(not available for all appliances)
2.
Standing against the wall
• on adjustable feet
• on steel plinth
• on concrete plinth
3.
Free standing
• on adjustable feet
• on steel plinth
• on concrete plinth
The appliances are suitable for setting up as single appliances
or as a group of appliances.
They can be positioned freely in the space provided, side by
side, against a wall or back-to-back. When installing side by
side, appliances are connected to a rail.
Different wall frames are used when setting up against a wall.
The ventilation engineer is responsible for assessing/planning
a technically correct ventilation.
G.2
Distances / walls
The appliance must not be installed on flammable walls. If an
appliance is set up next to or against temperature-sensitive
furniture or similar, keep a safety-distance of approximately 50
mm or fit some form of heat shield.
When installing the unit in the immediate vicinity of walls,
partitions, kitchen units, decorative panels, etc., we recom-
mend that these are either made from non-combustible
materials or coated/tiled in suitable, non-flammable materials.
The local fire protection regulations must be fully complied with.
G.3
Before installation
Depending on your model, prepare the following before the
appliance is installed and positioned correctly:
• Fastening elements, i.e. drill holes and insert dowels. You
can find accompanying notes in the relevant sections on
G.5
.
• Prepare water, gas and electrical connections and install a
shut-off valve, if necessary.
G.4
Installing on feet or plinth
G.4.1
Installation
To transport the appliance to the final location, see E
TRANSPORT, HANDLING AND STORAGE
.
Packaging should only be removed immediately before the unit is installed. To do so, take away all side and top parts of the
packaging in turn, as well as the fixing elements.
The unit remains on the transport pallet until it is at its final location.