8.3
Connect the dryer to the gas supply
1. Remove the cap from the end of the gas inlet.
2. Install a female 3/8” NPT adampter at the end of the dryer gas inlet, the male size of the adampter is R1/2”.
3. Attach the flexible metal gas line connector to the adapter.
4. Tighten the flexible gas line connection, using two adjustable wrenches.
Important
Apply pipe compound or PTFE tape to the threads of the adapter and dryer gas inlet.
A
B
C
fig.W01624
A
Adampter
B
3/8” NPT gas inlet
C
the flexible metal gas line
8.4
Gas installation
This gas appliance is built to run on natural gas (group I2H), commonly identified by the nameplate on the dryer. The
following table lists the country abbreviations.
AL
Albania
IS
Iceland
AT
Austria
IT
Italy
BE
Belgium
JP
Japan
BG
Bulgaria
LT
Lithuania
CH
Switzerland
LU
Luxembourg
CY
Cyprus
LV
Latvia
CZ
Czech Republic
MK
Republic of Macedonia
DE
Germany
MT
Malta
DK
Denmark
NL
Netherlands
EE
Estonia
NEC
Non-europeancountries
ES
Spain
NO
Norway
FI
Finland
PL
Poland
FR
France
PT
Portugal
GB
UnitedKingdom
RO
Romania
GR
Greece
SE
Sweden
HR
Croatia
SI
Slovenia
HU
Hungary
SK
Slovakia
IE
Ireland
TR
Turkey
You should check the kind of energy gas that is available in your place.
There are many gas types of the same kind but the machine should be equipped with different kinds of injectors de-
pending on the gas type.
Содержание TE1220E
Страница 1: ...Installation manual Tumble dryer TE1220E TE1220G Original instructions 0180500987B EN 2022 01 04 ...
Страница 2: ......
Страница 4: ......
Страница 30: ...30 Installation manual 6 Remove the two screws with cross screwdriver D fig W01627 D the two screws ...
Страница 40: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...