Installation manual
37
When the installation is completed remount the cover panel and check:
• That the drum is empty.
• That the machine operates by connecting the power to the machine and start a program with heat.
7.5
Electrical connections
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended fuse
A
Electric heated
machines
220–240V 1 ~
50/60
6.0
7.0
32
220–230V 3 ~
50/60
9.0/13.5
10.0/14.5
32/50
240V 3 ~
50/60
9.0/13.5
10.0/14.5
25/32
380–415V 3N ~
50/60
9.0/13.5
10.0/14.5
16/25
440V 3 ~
50/60
9.0/13.5
10.0/14.5
16/20
480V 3 ~
60
9.0/13.5
10.0/14.5
16/20
115V 3 ~
60
13.2
14.3
80
Gas- and Steam
heated machines
220–240V 1 ~
50/60
*
1.2
10
220–240V 3 ~
50/60
*
1.0
10
380–415V 3N ~
50/60
*
1.0
10
440V 3 ~
50/60
*
1.0
10
480V 3 ~
60
*
1.0
10
Machines with heat
pump
220–240V 1 ~ / 1N ~
50/60
*
5.5
25
380–480V 3 ~ / 3N ~
50/60
*
6.5
10
Machines with heat
pump with DSC
(Drum Speed
Control)
380–415V 3 ~ / 3N ~
50/60
*
6.5
13
* Total power and recommended fuse does not depend on the heating power in those cases.
Содержание TD6-14
Страница 1: ...Installation manual Tumble dryer TD6 14 Type N2 Original instructions 438905900 EN 2022 09 12 ...
Страница 2: ......
Страница 28: ...28 Installation manual Demount the lower side panel 3x fig X00979E Disconnect the NTC sensor fig X01226B ...
Страница 59: ......
Страница 60: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...