20
20
7
6308
3 AC
6307
N
GND
L1
L2
L3
External connection
Max. 1.25A
X2
X1
N
GND
L1
L2
L3
External connection
Max. 1.25A
X2
X1
3N AC
6
6309
N
GND
L1
L2
L3
X2
External connection
Max. 1.25A
X1
1 AC
8
6330
Single-phase connection
Connect Earth wire to GND terminal, Live to
terminal L1 and Neutral to terminal N as shown
in the example in the fi gure.
When the installation is completed, check:
• That the drum is empty.
• Turn on the main switch and choose a drying
program. Start the machine.
Three phase connection
Connect Earth wire to GND terminal, Live to
terminal L1, L2, L3 and Neutral to terminal N
(3N AC only) as shown in example "3 AC"
and "3N AC" in the fi gure.
When the installation is completed, check:
• That the drum is empty.
• Turn on the main switch and choose a drying
program. Start the machine.
External connection (3NAC)
A special connection terminal is located at the
mains connection.
The connection terminal is used for:
Connection/control of external fan or a condeser.
Max. connected load is 1.25A.
Marine version (3AC)
External connection
A special connection terminal is located on the
tumbler motor bracket.
The terminal for external control is equipped with
110V/max. 100mA and is intended solely for the
operation of a contactor (external control of a
fan).
Max. connected load is 100mA.