MODELS: SB915SJ*05
SB915WJ*05
FAULT RECALL, OUTPUT TEST
SB925SJ*05
SB925WJ*05
FAULT & OUTPUT INDICATION
Fault Recall and Output Test (SB925)
O
PERATION
I
TEM
I
NPUT
O
UTPUT
Enter Test Mode
Switch dishwasher off by pressing the ‘POWER’
Button
All off
Press & hold ‘PROGRAM’ Button &
‘START/PAUSE’ Button then switch power on.
Keep holding the 2 Button for 2 sec.
‘SENSOR’ LED flashing Display show '1C'
Select F/O Test
Press ‘PROGRAM’ Button
‘RINSE’ LED flashing Display shows '2C'
Enter F/O Test
Press ‘START/PAUSE’ Button
‘RINSE’ LED on. Display & buzzer showing the last occurred fault (see
‘Fault Indication’ table Page 20)
Press ‘PROGRAM’ Button
Display & buzzer showing the 2
nd
last occurred fault
Press ‘PROGRAM’ Button
Display & buzzer showing the 3
rd
last occurred fault
Press ‘PROGRAM’ Button
‘FRAGILE’ LED on Display shows ‘4’ buzzer beeps 4 times. Regeneration
valve open (see ‘Output Indication’ table for details Page 20)
Press ‘PROGRAM’ Button
Display shows ‘5’ buzzer beeps 5 times. Drain pump on
Press ‘PROGRAM’ Button
Display shows ‘6’ buzzer beeps 6 times. Inlet valve open (only when level
P1 is not detected)
Press ‘PROGRAM’ Button
Display shows ‘7’ buzzer beeps 7 times. Heater on (only when level P1 is
detected)
Press ‘PROGRAM’ Button
Display shows ‘8’ buzzer beeps 8 times. Recirculation pump on
Press ‘PROGRAM’ Button
Display shows ‘9’ buzzer beeps 9 times. Detergent dispenser open
(dispenser may open up to 20 sec later)
Press ‘PROGRAM’ Button
Display shows ‘10’ buzzer beeps 10 times. Drying Fan on
Press ‘PROGRAM’ Button
‘RINSE’ LED on. Display & buzzer showing the last occurred fault
Press ‘PROGRAM’ Button
Repeat
Exit F/O Test
Switch off Power Button
Fault Indication (SB915/SB925)
F
AULT
N
AME
D
ISPLAY
C
USTOMER
C
AN
S
EE
S
HORT
E
XPLANATION
W
HAT
H
APPENS
?
No Fault
i 0
--
Not Filling
i10
Yes
Pressure switch is not set after 60 secs of
filling
Program stops
Not Draining
i20
Yes
Pressure switch is not reset after 120 secs of
draining
Program stops
Flood Control
i30
Yes
Inlet valve fault or 2
nd
pressure switch is set.
Overflow Leak Detection Switch set (
SB925
only)
Program stops
Recirculating Pump
Triac Short Circuit
i50
Yes
Tacho signals are detected while recirculation
pump is not on
Program stops
Not Heating
i60
No
Temperature rise <1.5
o
C within 3 min during
heating
Program continues without heating
NTC Fault
i70
No
NTC short or open circuit
Program continues without heating
EEPROM Fault
i80
No
Communication error with external
EEPROM
MCF/CCF Check
Sum Fault
i90
No
Check sum MCF or CCF is not right. Only
detected after switching on.
(Program software not working)
Program selection not possible
Turbidity Sensor
Fault (
SB925
only)
ib0
No
Turbidity signal required for calibration not
reached in 15 sec
Program continues with maximum turbidity
response
Tacho Fault
id0
No
No tacho signal detected when circular pump
is on
Program continues. Circular pump without
speed control. No heating
Filling Time Fault
iF0
No
Filling timeout
Program continues with less water
Output Indication (SB915/SB925)
T
ESTED
A
CTUATOR
D
ISPLAY
B
UZZER
B
EEPS
COMMENT
Regeneration Valve
‘4’
4 times
Not available on these models
Drain Pump
'5'
5 times
Inlet Valve
‘6’
6 times
Only when pressure switch is not set
Heater
‘7’
7 times
Only when pressure switch is set
Recirculation Pump
‘8’
8 times
Detergent Dispenser
‘9’
9 times
Drying Fan
‘10’
10 times
Page 25 DW161