Electrolux RM 6501 Скачать руководство пользователя страница 6

If the refrigerator is not cooling sufficiently, the
reason may be:
1.

Inadequate ventilation of the cooling unit due to the
intake and/or exhaust air vents being partly or
completely blocked.

2.

The evaporator is frosted up.

3.

The thermostat setting is incorrect .

4.

Gas pressure is incorrect - please check the pressure
regulator on the gas container.

5.

The ambient temperature is too high.

6.

Too much food is loaded at one time.

7.

The door is not properly closed or the magnetic
sealing strip is defective.

If the refrigerator still does not work properly, call a
service technician.

WARNING! The sealed cooling system must not
be opened, since it contains corroding chemi-
cals under high pressure.

MAINTENANCE

Always turn to a qualified service technician who is
familiar with LP gas systems and refrigerator.
We recommend that a service technician check the
refrigerator once a year.

Check all connections in the LP gas system for gas
leaks. Connections can be tested for leaks using a
soap solution. Do not use a naked flame! If there is
any suspicion of damage, call for a service technician.

The ventilation openings are unobstructed.

The Instruction Manual is available.

Check that the burner is clean and free from combus-
tible material.

SOME USEFUL HINTS

Make sure that:

The refrigerator is not operating on 12 V when the
vehicle is parked; otherwise you will drain the car
battery in a short time.

Defrosting is carried out periodically

The refrigerator is clean and dry with the door left
open when it is not to be used for some time.

Liquids or items with a strong odour are well packed.

The ventilation openings are unobstructed.

The doors are secured by means of the both travel
catches when the caravan is on the move.

SERVICE AND SPARE PARTS

Service and spare parts are obtainable from your dealer
or Electrolux - consult the telephone directory.

INSTALLATION INSTRUCTIONS

REPOSITIONING THE HINGES

The refrigerator is equipped with reversible doors.
A special door reversing kit must be used to reverse the
doors.
For further information, contact your dealer or Electrolux.

DOOR PANEL

Door panels can easily be fitted or changed. The dimen-
sions of the panels must be:

Model

RM 6501

Height

upper door

265 

±

1mm

lower door

833 

±

1mm

Width

483 

±

1mm

Thickness max.

    4     mm

Before starting the mounting work, check that the panel
dimensions are in compliance with those given in the
table and the instructions are read thoroughly.
When mounting the panel, proceed as follows:

Upper door

remove the two screws holding the control panel, pull
out the two knobs (energy selector and thermostat)

unscrew the upper hinge pin and remove the door

unscrew the upper part of the door frame, remove the
old panel

insert the new panel and push the panel downwards 

fasten the upper part of the door frame with its three
screws

please note that the panel must be changed on the
lower door, before the upper door can be mounted

lower door

unscrew the middle hinge pin and remove the door

unscrew the lower part of the door frame, remove the
panel stop (2x) and remove the old panel

insert the new panel and push the panel upwards, put
the panel stop back in place and fasten the lower part
of the door frame with its three screws

replace the lower door

replace the upper door

replace the control panel with its two screws and put
on the knobs.

14

Содержание RM 6501

Страница 1: ...822 70 90 02 RA RM 2D 0402 RM 6501 MANUAL CARAVAN Español pagina 35 Deutsch Seite 3 English page 11 Svenska sida 27 Français page 19 Suomi sivu 44 ...

Страница 2: ......

Страница 3: ...erator was delivered DATA PLATE Check the data plate inside the refrigerator to ensure that you have received the right model The data plate contains e g the following details Model designation RM Product number Serial number Voltage volts Gas pressure mbar Since these details will be needed if you have to contact service personnel it is a good idea to make a note of them here CONTENTS OPERATING I...

Страница 4: ... to activate the flame failure device then release it If the lamp start flashing again repeat step 4 6 To terminate gas operation turn the knob A to OFF position 230 240 V operation Before operating the refrigerator check that the voltage stated on the data plate is the same as the main voltage in use Turn the thermostat knob D to its highest coldest position Set the energy selector A to position ...

Страница 5: ...of detergent But not the door gasket which should only be cleaned with soap and water and then thoroughly dried The cooling unit behind the refrigerator should be cleaned with a brush from time to time but make sure that the refrigerator is switched off when doing this HEATING CABLE During the summer months of high temperatures and humidity the metal frame between the freezer and fresh food compar...

Страница 6: ...strong odour are well packed The ventilation openings are unobstructed The doors are secured by means of the both travel catches when the caravan is on the move SERVICE AND SPARE PARTS Service and spare parts are obtainable from your dealer or Electrolux consult the telephone directory INSTALLATION INSTRUCTIONS REPOSITIONING THE HINGES The refrigerator is equipped with reversible doors A special d...

Страница 7: ...ith the refrigerator in place drive the screws through the lining of the refrigerator into the walls of the enclosure There must not be more than 3 mm of clearance be tween refrigerator and enclosure on each side If neces sary wooden strips or similar should be fitted Note This is the only approved means of securing the refrigerator to the enclosure and to the vehicle Fasteners penetrating other p...

Страница 8: ...LIED TO THE REFRIGERATOR IS AT THE CORRECT PRESSURE SEE THE REDUCING VALVE ON THE LP GAS CONTAINER The gas installation should only be carried out by a person experienced in gas fitting It is recommended that the gas pipe feeding the refrigerator is so arranged that it is possible to turn off the supply of the refrigerator VENTILATION OF THE UNIT min ventilation height min 510 Condenser 20 40 385 ...

Страница 9: ...nd Yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol or coloured Green or Green and Yellow the wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Black the wire which is coloured Brown must be connected to the terminal which is marked with the letter L or coloured Red WARNING THIS A...

Страница 10: ...mm Depth incl cooling unit with door 545 mm without door 495 mm Recess dimensions Height 1248 mm Width 530 mm Depth 510 mm Capacity Gross 135 litres Net 124 5 litres frozen food compt 23 5 litres Weight without packaging 44 kg Electrical data Input 230 240 volt 220 watt 12 volt 175 watt Energy consumption in 24h 3 kWh LP gas data Input max 0 34 kW Energy consumption in 24h 300 g Cooling medium Amm...

Отзывы: