Electrolux RM 6501 Скачать руководство пользователя страница 4

OPERATING INSTRUCTIONS

CONTROLS

FIG. 1
The refrigerator can be run on 230-240 V, 12 V or LP
gas. Changing between these modes of operation is
carried out by means of the control buttons positioned
as shown in fig. 1.
The energy selector (A) can be set at either "AC" (230-
240 V), "DC" (12 V), "GAS" (LP gas) or "OFF".

An indicator lamp (B) at the control panel flashes when
the automatic igniter attempts to light the burner.
Otherwise this lamp is off.

The refrigerator is fitted with a safety device that
automatically shuts off the supply of gas if the flame goes
out. The safety device can be operated manually by
pressing the button (C).

The refrigerator temperature is controlled by a thermo-
stat (D) when the refrigerator runs on 230-240 V and LP
gas. Please note that the thermostat has no "off" position
when the refrigerator runs on LP gas.

STARTING THE REFRIGERATOR

All references are to fig. 1.

LP Gas operation

After initial installation, servicing, or changing gas cylinders
etc., the gas pipes may contain some air that should be
allowed to escape by briefly turning on the refrigerator or
other appliances. This will ensure that the flame lights
immediately.

To start gas operation:
1.

Open the shut off valve of the gas bottle (check that
there is enough gas). Open any on-board shut-off
valve.

2.

Set the thermostat knob (D) to the highest setting.

3.

Turn the energy selector (A) to position "GAS".
A ticking sound will be heard and the lamp (B) will
start flashing.

4.

Push the button (C) in until it reaches the bottom -
and hold. This opens the flame failure device and
allows gas to flow to the burner.

5.

When the flame lights, the sparking stops automati-
cally and the lamp stops flashing.

6.

Hold the button (C) an additional 10-15 seconds to
activate the flame failure device, then release it.
If the lamp start flashing again, repeat step 4-6.

To terminate gas operation, turn the knob (A) to "OFF"
position.

230-240 V operation

Before operating the refrigerator, check that the voltage
stated on the data plate is the same as the main voltage
in use.

Turn the thermostat knob (D) to its highest (coldest)
position.

Set the energy selector (A) to position "AC".

12 V operation

Only operate your refrigerator on 12 V when the engine
of the vehicle is running - otherwise your battery will soon
be discharged.

Set the energy selector (A) to position "DC".

REGULATING THE TEMPERATURE

The position number refers to fig.1.
It will take a few hours for the refrigerator to reach normal
operating temperature. So we suggest you start it well
in advance of a trip and if possible store it with precooled
foodstuffs.
On 230-240 V operation and LP gas operation the
refrigerator is controlled by a thermostat and the thermo-
stat knob (D) should be set at 3-5. If a lower (colder)
temperature is desired set the thermostat to a higher
figure.
On 12 V operation the refrigerator works continuously.

TRAVEL CATCH

The refrigerator is equipped with two travel catches.
Make sure that both are engaged when the caravan is
on the move.

FOOD STORAGE

Always keep food in closed containers. Never put hot
food in the refrigerator; allow it to cool first.

Never keep items in the refrigerator that might give
off flammable gases.

The frozen food compartment is intended for the storage
of frozen food and for making ice. It is not suitable for
freezing items of food.
Never put bottles or cans of soft drinks in the frozen food
storage compartment as they may burst when freezing.

Most kinds of frozen food can be stored in the frozen
food compartment for about a month. This period of time
may vary, however, and it is important to follow the
instructions on the individual packages.

A

C

D

B

12

Содержание RM 6501

Страница 1: ...822 70 90 02 RA RM 2D 0402 RM 6501 MANUAL CARAVAN Español pagina 35 Deutsch Seite 3 English page 11 Svenska sida 27 Français page 19 Suomi sivu 44 ...

Страница 2: ......

Страница 3: ...erator was delivered DATA PLATE Check the data plate inside the refrigerator to ensure that you have received the right model The data plate contains e g the following details Model designation RM Product number Serial number Voltage volts Gas pressure mbar Since these details will be needed if you have to contact service personnel it is a good idea to make a note of them here CONTENTS OPERATING I...

Страница 4: ... to activate the flame failure device then release it If the lamp start flashing again repeat step 4 6 To terminate gas operation turn the knob A to OFF position 230 240 V operation Before operating the refrigerator check that the voltage stated on the data plate is the same as the main voltage in use Turn the thermostat knob D to its highest coldest position Set the energy selector A to position ...

Страница 5: ...of detergent But not the door gasket which should only be cleaned with soap and water and then thoroughly dried The cooling unit behind the refrigerator should be cleaned with a brush from time to time but make sure that the refrigerator is switched off when doing this HEATING CABLE During the summer months of high temperatures and humidity the metal frame between the freezer and fresh food compar...

Страница 6: ...strong odour are well packed The ventilation openings are unobstructed The doors are secured by means of the both travel catches when the caravan is on the move SERVICE AND SPARE PARTS Service and spare parts are obtainable from your dealer or Electrolux consult the telephone directory INSTALLATION INSTRUCTIONS REPOSITIONING THE HINGES The refrigerator is equipped with reversible doors A special d...

Страница 7: ...ith the refrigerator in place drive the screws through the lining of the refrigerator into the walls of the enclosure There must not be more than 3 mm of clearance be tween refrigerator and enclosure on each side If neces sary wooden strips or similar should be fitted Note This is the only approved means of securing the refrigerator to the enclosure and to the vehicle Fasteners penetrating other p...

Страница 8: ...LIED TO THE REFRIGERATOR IS AT THE CORRECT PRESSURE SEE THE REDUCING VALVE ON THE LP GAS CONTAINER The gas installation should only be carried out by a person experienced in gas fitting It is recommended that the gas pipe feeding the refrigerator is so arranged that it is possible to turn off the supply of the refrigerator VENTILATION OF THE UNIT min ventilation height min 510 Condenser 20 40 385 ...

Страница 9: ...nd Yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol or coloured Green or Green and Yellow the wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Black the wire which is coloured Brown must be connected to the terminal which is marked with the letter L or coloured Red WARNING THIS A...

Страница 10: ...mm Depth incl cooling unit with door 545 mm without door 495 mm Recess dimensions Height 1248 mm Width 530 mm Depth 510 mm Capacity Gross 135 litres Net 124 5 litres frozen food compt 23 5 litres Weight without packaging 44 kg Electrical data Input 230 240 volt 220 watt 12 volt 175 watt Energy consumption in 24h 3 kWh LP gas data Input max 0 34 kW Energy consumption in 24h 300 g Cooling medium Amm...

Отзывы: