3.4 Bypass diameters
BURNER
Ø BYPASS1) 1/100 mm
Auxiliary
29 / 30
Semi-rapid
32
Rapid
42
Oven
44
1) Type of bypass depends on model.
3.5 Gas burners for NATURAL GAS G20 13 mbar
BURNER
NORMAL POW‐
ER kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Rapid
2.6
0.78
137
Semi-rapid
1.9
0.5
111
Auxiliary
0.9
0.4
82
Oven
2.1
0.9
110 o
Grill
1.9
-
115
3.6 Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POW‐
ER kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Rapid
2.9
0.80
119
Semi-rapid
1.85
0.43
96
Auxiliary
0.95
0.35
70
Oven
2.1
0.90
104 o
Grill
1.9
-
108o
3.7 Gas burners for LPG G30 30 mbar
BURNER
NORMAL
POWER kW
REDUCED
POWER kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS
FLOW g/h
Rapid
3.0
0.72
88
218
Semi-rapid
1.9
0.43
71
138
Auxiliary
0.95
0.35
50
69
Oven
2.1
0.90
71
153
Grill
1.9
-
71
138
ENGLISH
9
Содержание RKG500002W
Страница 1: ...RKG500002W RKG500002X EN Cooker User Manual ...
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ...www electrolux com shop 867365250 B 332021 ...