75
ENGLISH
B.2.6 Reversing opening of fully insulated doors
ATTENTION
Disconnect the appliance
from the power supply be-
fore carrying out the door
reversing procedure.
The refrigerated cupboards are normally supplied with right
opening.
When changing to left opening, proceed as follows:
`
`
open the control panel, loosening the 2 screws located
between the panel and door;
`
`
remove the cap located on the left side and refit it on the
right side of the control panel;
`
`
undo the 2 screws of the upper bracket “
A
”, the hinge
fastening screw “
B
” and the 2 fixing screws (
Detail 1
);
`
`
remove the cap “
C
” from the left side and place it on the
right side (
Detail 2
);
`
`
remove the door, pull out the hinge from its seat, move
it from the right to the left and fit it in the hole as shown
in the figure (
Detail 3
);
`
`
position the upper bracket “
A
” between the door and the
roof of the appliance, tightening the fixing screws (
Detail 3
);
`
`
remove the lower bracket “
D
” from its seat and refit it in
the special seat on the opposite side (
Detail 4
);
`
`
position the door on the lower bracket “
D
”;
`
`
before tightening the screws, align the door with the
cabinet panel, adjusting the lower and upper brackets
and making sure the seal is perfectly fitted on all sides;
`
`
then tighten the bracket fixing screws;
`
`
close the control panel again, securing the 2 screws (pre-
viously loosened) between the panel and door.
B
A
Detail 1
2
3
1
C
Detail 2
2
3
1
Detail 3
D
Detail 4