9.2.5 “i40” code family: analogue pressure switch
9.2.5.1 “i41”
code
-
The alarm is defined if no signal is detected from the analogue pressure switch for more than 1 sec
or if the signal is out of range.
-
The programme stops and the error is displayed.
9.2.5.2 “i42”
code
-
The alarm is defined if the signal originating from the sensor is not stable enough or is out of range
for an empty appliance.
-
The calibration is performed during the activation of the drain pump and immediately after to
guarantee that if the non-return valve is not sealed, the backflow of water does not corrupt the actual
calibration.
9.2.6 “i50” code family: Washing motor problems
9.2.6.1 “i51” code – asynchronous motor
-
Acoustic signal and visual alarm, depending on the appliance customisation; the programme is
suspended.
-
The washing pump runs without being activated by the software, the cause is a short-circuit.
-
The heating element is not activated.
-
If the alarm occurs, the fill solenoid valve is activated up to the level pressure switch tripping point,
then the cycle is suspended.
-
Time limit set: 8 sec.
9.2.6.2 “i52” code – synchronous motor
-
The alarm is signalled when an abnormal extra current of 1.3 Amps is detected.
9.2.6.3 “i53” code – asynchronous motor
-
The alarm is signalled when a current above the maximum limit allowed of 1.3 Amps is detected.
9.2.6.4 “i54” code – inverter motor with rotor locked
-
The alarm is signalled when the motor is locked at the start or during its actual activation.
-
Possible causes may be the presence of dirt, too large a load, mechanical problems on impeller.
9.2.6.5 “i55” code – motor control board over voltage
-
The alarm is signalled when the voltage detected on the motor control board is more than 400 V.
9.2.6.6 “i56” code – motor control board under voltage
-
The alarm is signalled when the voltage detected on the motor control board is less than 255 V.
9.2.6.7 “i57”
code
-
The alarm is signalled if a voltage of more than 440 V or less than 215 V is detected.
9.2.6.8 “i58” code – washing pump connection
-
The alarm is signalled if an incorrect connection of the pump is detected, based on the current
measurements check.
-
Time limit set: 2 sec.
9.2.6.9 “i59” code – current measurement error on motor control board
-
The alarm is signalled if there is an error in reading the current on the motor control board
-
The condition is verified by the sum of currents of each of the phases, which should be nearly zero:
if this sum is more than 40mA for longer than 300 msec then an error condition occurs.
Содержание ProClean RealLife EDW1xxx-2G Series
Страница 6: ...SOE PR 6 599 72 48 93 3 2 Fully Integrated EDW1953 EDW1103 ...
Страница 7: ...SOE PR 7 599 72 48 93 3 3 Built In ...
Страница 8: ...SOE PR 8 599 72 48 93 EDW750 EDW1850 EDW1950 EDW3510 EDW2500 SWISS ...
Страница 9: ...SOE PR 9 599 72 48 93 EDW 500 EDW 503 EDW 1503 ...
Страница 14: ...SOE PR 14 599 72 48 93 6 2 3 EDW750 6 2 4 EDW1850 1950 6 2 5 EDW1953 TOUCH ...
Страница 25: ...SOE PR 25 599 72 48 93 7 13 EDW750 7 14 EDW1850 1950 7 15 EDW1953 TOUCH ...
Страница 54: ...SOE PR 54 599 72 48 93 10 14 EDW1xxx 2G operating diagram ...
Страница 55: ...SOE PR 55 599 72 48 93 10 15 EDW3000 operating diagram single phase motor ...
Страница 56: ...SOE PR 56 599 72 48 93 10 16 EDW3000 operating diagram three phase Inverter motor ...