![Electrolux ProClean RealLife EDW1xxx-2G Series Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/electrolux/proclean-reallife-edw1xxx-2g-series/proclean-reallife-edw1xxx-2g-series_service-manual_2382017018.webp)
SOE/PR
18
599 72 48-93
7.2 EDW503
7.2.1 Diagnostics mode, alarm reading and testing
1. Hold down the
PROGRAMMES
button
2. Turn the appliance on at the
ON/OFF
button
ª
LED
L1
flashes
ª
LEDs
L2
and
L3
are turned on
3. Wait for LEDs
L2
and
L3
to be turned off
4. Press
the
PROGRAMMES
button
ª
the CYCLE END LED shows the first alarm stored with a sequence of flashes
5. Press the PROGRAMMES button twice more to display the other two alarms stored
ª
the CYCLE END LED shows the alarms
6. From the 4th activation, the individual components testing begins according to the defined sequence
ª
LED
L2
is turned on permanently for the duration of the components test
ª
4th activation: regenerating solenoid valve
ª
5th activation: drain pump
ª
6th activation: water fill to level solenoid valve (level of water reached)
ª
7th activation: heating (only if the level of water is reached)
ª
8th activation: washing pump
ª
9th activation: detergent/rinse aid dispenser
ª
10th activation: drying fan
ª
11th activation: the cycle is repeated from the first alarm
All the positions can be repeated by pressing button
S2
in sequence.
The components are powered with the appliance door open and shut.
If the PROGRAMMES button is not pressed for 60 seconds, you automatically quit diagnostics
mode.
7.2.2 Deleting alarm memory/LED test
1. Hold down the
PROGRAMMES
button
2. Turn the appliance on at the ON/OFF button
ª
LED
L1
flashes
ª
LEDs
L2
and
L3
are turned on
3. Press the PROGRAMMES button before LEDs
L2
and
L3
are turned off
ª
LED
L2
flashes
ª
LEDs
L1
and
L3
are turned on
4. Wait for LEDs
L1
and
L3
to be turned off
5. Press
the
PROGRAMMES
button
ª
all LEDs flash and the buzzer sounds
Содержание ProClean RealLife EDW1xxx-2G Series
Страница 6: ...SOE PR 6 599 72 48 93 3 2 Fully Integrated EDW1953 EDW1103 ...
Страница 7: ...SOE PR 7 599 72 48 93 3 3 Built In ...
Страница 8: ...SOE PR 8 599 72 48 93 EDW750 EDW1850 EDW1950 EDW3510 EDW2500 SWISS ...
Страница 9: ...SOE PR 9 599 72 48 93 EDW 500 EDW 503 EDW 1503 ...
Страница 14: ...SOE PR 14 599 72 48 93 6 2 3 EDW750 6 2 4 EDW1850 1950 6 2 5 EDW1953 TOUCH ...
Страница 25: ...SOE PR 25 599 72 48 93 7 13 EDW750 7 14 EDW1850 1950 7 15 EDW1953 TOUCH ...
Страница 54: ...SOE PR 54 599 72 48 93 10 14 EDW1xxx 2G operating diagram ...
Страница 55: ...SOE PR 55 599 72 48 93 10 15 EDW3000 operating diagram single phase motor ...
Страница 56: ...SOE PR 56 599 72 48 93 10 16 EDW3000 operating diagram three phase Inverter motor ...