Pin No.
Signal
I/O
Description
87
P41
IN
Signal similar to AN10.
When either G13 line on key matrix is touched, acorresponding signal will be input into
P41.
88
P42
IN
Signal similar to AN10.
When either G12 line on key matrix is touched, acorresponding signal will be input into
P42.
89
IRQ0
IN
Signal synchronized with commercial power source frequency.
This is the basic timing for time processing of LSI.
90
AVCC
IN
A/D converter power source voltage.
The power source voltage to drive the A/D converter in the LSI. Connected to GND.
91
AN0
IN
Used for initial balancing of the bridge circuit (absolute humidity sensor). This input is an
analog input terminal from the AH sensor circuit, and connected to the A/D converter built
into the LSI.
92
AN0-AN1
IN
AH sensor input.
This input is an analog input terminal from the AH sensor circuit, and connected to the
A/D converter built into the LSI.
93
AN2
IN
To input signal which communicates the door open/close information to LSI.
Door closed; "H" level signal(0V).
Door opened; "L" level signal(-5V).
94
AN3
IN
Terminal not used.
95-98
AN4-AN7
IN
Terminal to change cooking input according to the Model.
By using the A/D converter contained in the LSI, DC voltage in accordance with the Model
in operation is applied to set up its cooking constant.
99
AN8
IN
Input terminal to judge the model.
The signal out of P16 will be input into AN8 through G2 line on key matrix. The LSI will
judge the model by this signal.
100
AN9
IN
Signal similar to AN10.
When either G11 line on key matrix is touched, a corresponding signal will be input into
AN9.
16.7 msec.
H : GND