![Electrolux GLMV169DB Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/electrolux/glmv169db/glmv169db_service-manual_96956027.webp)
25
GLMV169DB
GLMV169DQ
GLMV169DS
PLMV169DC
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power transformer.
5. Using an ohm-meter, check between the terminals as described in the following table:
MEASURING POINT
INDICATION OF OHM-METER
Between N and H
Open Circuit
Between terminal N and GRY
Short Circuit
Between terminal H and RED
Short Circuit
If incorrect readings are obtained, replace the noise filter.
6. Reconnect all leads removed from components during testing.
7. Re-install the outer case (cabinet).
8. Reconnect the power supply cord after the outer case is installed.
9. Run the oven and check all functions.
P
NOISE FILTER TEST
NOISE FILTER UNIT
MONITOR
FUSE
NOISE SUPPRESSION COIL
LINE CROSS CAPACI-
TOR 0.22uF/ AC 250V
LINE BYPASS CAPACITOR
LINE BYPASS CAPACITOR
0.0033uF/ AC
125V
0.0033uF/ AC
125V
RED
GRY