background image

Tech Sheet – Laundry Center FFL(E/G)3911/4033

                                                             GD000006035-B

                                    

 

 

 

 

 

 

 

 

 

 

Page 8 of 11 

Alarm 

Code 

Alarm 

Description 

Fault 

Condition 

Possible 

Fault 

Machine 

Action/Status  

Action to 

Clear 

E5F  Motor Control Board Fault 

Motor Control Board control board is 

continuously in reset  

Wiring 

Motor control board 

Main board 

Cycle ends 

ON/OFF 

RESET 

 

 

 

 

 

 

 

 

 

 

 

 

E71 

Washing NTC failure 

Wrong input signal to microprocessor 

 (open circuit or short circuit) 

Wiring open 

Washing NTC 

Wiring or main board 

Water load not temperature 

controlled 

START 

RESET 

 

 

 

 

 

 

E87 

User Interface 

microcontroller fault

 

User interface microcontroller damaged 

User interface 

No actions to be performed. 

If still present replace the 

User Interface Board 

START 

ON/OFF 

RESET 

 

 

 

 

 

 

E91 

User interface and main 

board communication error 

Communication problem between user 

interface and main board 

Wiring  

User interface  

Main Board 

Motor control board 

--- 

RESET 

E92 

User interface and main 

board protocol  

incongruence error 

Protocol communication between user interface 

and main board not compatible 

Main board 

User interface board 

Cycle blocked 

OFF/ON 

E93 

Machine configuration 

error 

Incorrect configuration of appliance 

Main board 

Cycle blocked 

OFF/ON 

E94  Cycle Configuration error 

Incorrect configuration of washing cycles 

Main board 

Cycle blocked 

OFF/ON 

E97 

Software selector and 

cycles configuration error 

Incongruence between  

program selector and cycle configuration 

Main board 

Cycle blocked 

RESET 

E98 

Motor control to main 

board software error 

Protocol communication between Motor 

Control Board and MB not aligned 

Main board 

 Motor control board 

Cycle blocked 

OFF/ON 

E9C 

User interface 

configuration fault 

Configuration wrongly or not received 

User interface 

No actions 

ON/OFF 

START 

RESET 

 

 

 

 

 

 

EB1 

(EH1) 

Power supply frequency 

out of limits  

Power supply period lower/higher than 

configured values 

AC input 

Main board 

Wait for improved power 

supply conditions 

OFF/ON 

EB2 

(EH2) 

Power supply voltage too 

high 

MAIN_V sensing input voltage value greater 

than configured value 

High AC input voltage 

Main board 

Wait for improved power 

supply conditions 

OFF/ON 

EB3 

(EH3) 

Power supply voltage too 

low 

MAIN_V sensing input voltage value lower 

than configured value 

Low AC input voltage 

Main board 

Wait for improved power 

supply conditions 

OFF/ON 

Содержание FFLE3911QW

Страница 1: ...tches do not matter 2 If the unit is not plugged in plug in and skip to step 6 or do a full control reset as in steps 3 to 5 3 Hold the selector knob for 6 to 8 seconds and within 5 seconds complete steps 4 and 5 4 Move the temperature knob to the far right position CW and push the selector knob momentarily 1 second 5 The unit will indicate a full control reset by beeping 3 times then move the tem...

Страница 2: ...ption is available on the machine then the softener solenoid will also activate and the softener compartment will be filling up and siphoning cold water at the same time 6 Turn the Cycle Selector knob 5 clicks clockwise from Normal position The drum will stop and the drain pump will activate draining out any water in the tub After draining the clutch actuator will start moving continuously for abo...

Страница 3: ...e of test Water loading from the hot water valve Activated components Door lock hot water valve clutch motor UI behaviour None Working conditions Door locked water level lower then 140mm for max 5 minutes The clutch moves to the agitate position if it was in spin 3 Cold Water Valve Test Selector position Turn 2 clicks clockwise from the top Purpose of test Water loading from the cold water valve A...

Страница 4: ...tor UI behaviour None Working conditions Door locked drum stop run clutch to spin mode and drain until empty 10 seconds more Run clutch actuator for about 100 seconds 7 Drain and Spin Test Selector position Turn 6 clicks clockwise from the top Purpose of test Verify drain system and Pressure Sensor calibration procedure Activated components Door lock main motor drain pump UI behaviour None Working...

Страница 5: ...eating E5C Motor Control Board Over Voltage E5D Motor Control Board Unknown Message E5E Motor Control Board MB Communication E5F Motor Control Board Fault E71 Washing NTC failure E87 User Interface microcontroller fault E91 UI MB communication error E92 UI MB protocol incongruence error E93 Machine configuration error E94 Cycle Configuration error E97 Incongruence between selector and cycles confi...

Страница 6: ...g timed during each drain Drain pipe blocked Drain pump defective or rotor locked Pressure switch defective or blocked Drain pump not energized wiring or main board Cycle Paused after 2 attempts START ON OFF RESET E31 Pressure sensor fault Frequency of electronic pressure sensor out of limits Pressure sensor Wiring or main board Cycle abort RESET E32 Electronic pressure sensor calibration problems...

Страница 7: ...ng or motor control board Cycle abort ON OFF RESET E59 Motor not following No rotation detected for 3 seconds Drum mechanical locked Motor Wiring or motor control board Cycle abort ON OFF RESET E5A Motor control overheating High temperature on heat sink 88 C or NTC of motor control board open Drum weight overload Motor control board Motor Cycle abort ON OFF RESET E5H Motor control under voltage DC...

Страница 8: ... User interface board Cycle blocked OFF ON E93 Machine configuration error Incorrect configuration of appliance Main board Cycle blocked OFF ON E94 Cycle Configuration error Incorrect configuration of washing cycles Main board Cycle blocked OFF ON E97 Software selector and cycles configuration error Incongruence between program selector and cycle configuration Main board Cycle blocked RESET E98 Mo...

Страница 9: ...sor always to 0V or to 5V Main board Safety drain Cycle abort RESET EC6 Clutch Alarm Clutch positioning timeout to reach or failure to stay in desired position Clutch mechanism failure Main board defective Wiring connection problem Cycle abort EC7 Clutch triac sensing Failure The sensing of the clutch triac is out of the limits Clutch mechanism failure Main board Wiring connection problem Cycle ab...