14
6.5.2.1 If TA
﹥
TS+1
℃
, the outdoor fan operates. After 15 seconds, the compressor operates.
6.5.2.2 The compressor is on, if TA
≤
TS, this compressor will stop. If the outdoor fan operates for 3
minutes at least, it will stop after delaying for 5 seconds.
6.5.3. When the unit is off, the compressor stops at first, and the indoor/outdoor fan will stop after
delaying for 5seconds. (If it operates at heating mode, the outdoor fan will be off delaying for 30
seconds)
6.5.4. The ION/TIMER functions are valid at the cooling mode.
6.6 Drying mode
6.6.1. The unit operates at drying mode. If TA>13
℃
, outdoor fan turns on, and then the compressor
operates after 15 seconds later.
6.6.1.1 When TA<13
℃
, the compressor stops working. And the outdoor fan will stop delaying for 5
seconds until it operates for 3minutest.
6.6.1.2 When TA
≥
15
℃
, the outdoor fan operates, and the compressor will restart to operate after
15seconds.
6.6.2. The speed can’t be controlled at drying mode, and the indoor fan motor operates at low speed.
(TA-Ts)
℃
+1
0
Compressor on
Operation conditon
Compressor off
TA
℃
15
13
Compressor on
Operation conditon
Compressor off