12
Turn lightly the cable to make the
connection easier later.
Be careful not to let the drain hose
become slack.
Heat insulate the connecting pipe.
Be sure that the drain hose is located at
the lowest side of the buddle. Locating
at the upper side can cause drain pan to
RYHUÀRZLQVLGHXQLW
Never cross connect or interwind the
power wire with any other wiring.
Do not allow the piping to be exposed
out from the back of the indoor unit.
If part of the drain hose is positioned
inside the room, wrap it with insulating
materials so as to prevent condensed
water from dropping.
&RQQHFWWKHLQGRRUXQLW¿UVWWKHQWKH
outdoor unit.
Do not plug the cable to the indoor unit.
That must be done later.
Fixing lower hook
Do not route both refrigerant piping and
drain hose from the right side to the left
side to prevent big gap between the
indoor unit and the wall.
Drain hose
from the right side
Piping and cable
from the right side
7DNHRXWWKHSLSLQJIURPERG\FDVHZUDS
the piping, power cords, drain hose with the
tape and then make them pass through the
piping hose.
Do not put any object in the drain pan
located in the rear of the indoor unit, as the
condensed water is gathered there and
piped out of the room.
+DQJWKHPRXQWLQJVORWVRIWKHLQGRRUXQLWRQ
the upper hooks of the mounting plate and
FKHFNLILWLV¿UPHQRXJK
To ease the piping installation, put a spacer
between the indoor unit and the wall.
5HPRYHWKHVSDFHURQFH¿QLVKHG
Indoor Unit
Piping
insulation
Upper hook
Liquid pipe
Gas pipe
Connecting
cable
6 Press the lower left and right sides of the unit
against the mounting plate until the lower
hooks engage into their slots.
(QVXUHWKHXQLWLV¿UPO\¿WWHG
Drain hose
Drain hose
Mounting plate
7 The installation site should be 2 meters or more
DERYHWKHÀRRU
caution
Upper hook
Connecting
cable
Spacer
Mounting
plate