Technical Support - DMM
71/106
599 77 23-65 Rev. 03
Alarm
Code
Alarm Description
Fault Condition
Possible Fault
Machine Action/Status
Reset Key
E73
Input drying NTC failure
Voltage value out of limit
(open circuit or short
circuit)
Input drying NTC defective
Wiring or WD board defective
Drying heating phases
skipped
START
RESET
E74
Washing NTC
badly positioned
The washing temperature
does not increase
Washing NTC sensor badly positioned,
NTC sensor faulty,
Wiring or main board defective
Heating phases skipped
RESET
E83
Wrong selector reading
Selector position code
value not supported by the
configuration data
Wrong configuration data on microprocessor
Main board defective
Reset cycle
START
RESET
E84
Recirculation pump triac
sensing failure
Wrong input signal to
microprocessor
Main board defective
Safety Drain cycle.
Cycle stops with door
unlocked
RESET
E85
Recirculation pump triac
alarm
Incongruence between
triac sensing
and triac status
Recirculation pump defective
Wiring or main board defective
Safety Drain cycle.
Cycle stops with door
unlocked
RESET
E86
Selector table configuration
error
Incorrect configuration of
the User Interface
Wrong or missing selector
configuration data on
UI microprocessor -
User interface defective
---
START
ON/OFF
RESET
E87
User Interface microcontroller
fault
User interface
microcontroller damaged
User interface defective
No actions to be performed. If
still present replace the User
Interface Board
START
ON/OFF
RESET
E91
UI-MB
communication error
Communication problem
between UI and MB
Wiring defective, or
UI, MB, Motor, WD , Weight board defective,
---
RESET
E92
UI-MB protocol
incongruence error
Protocol communication
between UI and MB not
compatible
Main board incompatible with user interface board
Cycle blocked
OFF/ON
E93
Machine configuration error
Incorrect configuration of
appliance
Incorrect configuration data
Main board defective
Cycle blocked
OFF/ON
E94
Cycle Configuration error
Incorrect configuration of
washing cycles
Incorrect configuration data
Main board defective
Cycle blocked
OFF/ON
E97
Incongruence between
selector and cycles
configuration
Incongruence between
program selector and cycle
configuration
Incorrect configuration data
Main board defective
Cycle blocked
RESET
E98
FCV_MB protocol incong.
Error
Protocol communication
between FCV and MB not
aligned
Main board incompatible with FCV control board
Cycle blocked
OFF/ON
E9C
User Interface Configuration
fault
Configuration wrongly or
not received
Display Board
No actions
ON/OFF
START
RESET
E9E
UI touch fault
Touch display not working
Display Board
No actions
OFF/ON