SOI/DT 2007-11 dmm
53/69
599 70 39-88
11.2 Table of alarm codes
Alarm
Possible fault
Action/machine status
Reset
E11
Tap closed or water pressure too low; Drain tube improperly positioned; Water fill
solenoid valve is faulty; Leaks from water circuit on pressure switch; Pressure switch
faulty; Wiring faulty; PCB faulty.
Cycle is paused with door locked.
START/RESET
E12
Tap closed or water pressure too low; Drain tube improperly positioned; Water fill
solenoid valve is faulty; Leaks from water circuit on pressure switch; Pressure switch
faulty; Wiring faulty; PCB faulty.
Cycle is paused with door locked.
START/RESET
E13
Drain tube improperly positioned; Water pressure too low;
Water fill solenoid valve is faulty; Water circuit on pressure switch is leaking/clogged;
Pressure switch faulty.
Cycle is paused with door locked.
START/RESET
E21
Drain tube kinked/clogged/improperly positioned; Drain filter clogged/dirty; Drain
pump faulty; Pressure switch faulty; Wiring faulty; PCB faulty; Electrical current leak
between heating element and ground.
Cycle is paused (after 2 attempts).
START/RESET
E22
Drain tube kinked/clogged/improperly positioned; Drain filter clogged/dirty; Drain
pump faulty; Pressure switch faulty; Wiring faulty; PCB faulty; Electrical current leak
between heating element and ground.
Cycle is paused
START/RESET
E23
Drain pump faulty; Wiring faulty; PCB faulty.
Safety drain cycle - Cycle stops with
door unlocked.
RESET
E24
PCB faulty.
Safety drain cycle - Cycle stops with
door unlocked.
RESET
E31
Pressure switch; Wiring; Main PCB.
Cycle stops with door locked.
RESET
E32
Drain tube kinked/clogged/improperly positioned; Drain filter clogged/dirty; Drain
pump faulty; Water circuit on pressure switch; pressure switch;
Wiring; main board.
Cycle is paused.
START/RESET
E35
Water fill solenoid valve is faulty; Leaks from water circuit on pressure switch;
Pressure switch faulty; Wiring faulty; PCB faulty.
Cycle stops. Safety drain cycle.
Drain pump continues to operate (5
min. on, then 5 min. off, etc.).
RESET
E38
Water circuit on pressure switches; Pressure switches; Motor belt broken.
Heating phase is skipped.
ON/OFF RESET
E3A
PCB faulty.
Cycle stops with door locked.
RESET
E41
Door lock unit faulty; Wiring faulty; PCB faulty.
Cycle is paused.
START/RESET
E42
Door lock unit faulty; Wiring faulty; PCB faulty.
Current dispersion from heating element to ground.
Cycle is paused.
START/RESET
E43
Door lock unit faulty; Wiring faulty; PCB faulty. (Safety
drain
cycle) Cycle stops.
ON/OFF RESET
E44
PCB faulty.
(Safety drain cycle) Cycle stops.
ON/OFF RESET
E45
PCB faulty.
(Safety drain cycle) Cycle stops.
ON/OFF RESET
Содержание EWM21xx
Страница 2: ...SOI DT 2007 11 dmm 2 69 599 70 39 88 ...
Страница 57: ...SOI DT 2007 11 dmm 57 69 599 70 39 88 11 3 Diagram WM with UNIVERSAL MOTOR EWM 21xx ...
Страница 59: ...SOI DT 2007 11 dmm 59 69 599 70 39 88 11 4 Diagram WM with THREE PHASE ASYNCHRONOUS MOTOR EWM 25xx ...
Страница 61: ...SOI DT 2007 11 dmm 61 69 599 70 39 88 11 5 Diagram WD with UNIVERSAL MOTOR EWM 21xx ...
Страница 63: ...SOI DT 2007 11 dmm 63 69 599 70 39 88 11 6 Diagram WD with THREE PHASE ASYNCHRONOUS MOTOR EWM 25xx ...