SOI/DT 2007-11 dmm
43/69
599 70 39-88
10.3.2 Operating principle of flow meter
The main components of the flow sensor are:
1. Turbine (with magnet and
counterweight mounted on the
outside)
2.
Reed switch (normally open)
3. Magnet
4. Counterweight
Water entering the solenoid valve rotates the turbine (1) and magnet (3), which passes in front of the reed
switch (2), thus closing it. As this contact opens and closes, it generates pulses at a frequency that is a function
of water flow.
The turbine completes 230 revolutions for each litre of water. The operating range of the flow sensor is 0.2-10
bar.
Using the signal it receives, the microprocessor can calculate the number of litres of water passing through the
solenoid valve.
Mechanical jamming of solenoid valve
The solenoid valve may jam open without being actuated (which will cause flooding if the pressure switch
controlling the water level does not trip). If this occurs, the electronic control system (which continuously
monitors the flow sensor) will lock the door, start the drain pump and display an alarm.
Low water pressure
If the flow sensor does not generate a signal during water fill even though power is being applied to the solenoid
valve, the cause of this condition may be a closed water tap or clogged filter on the solenoid valve (with
consequent low water pressure). If this occurs, a warning will be displayed and the cycle will continue for five
minutes, after which time an alarm will be signalled.
The solenoid valve controlling residual condensed water operates during the drying phase on washer-dryers.
The alarm is deactivated because the amount of water fill is very small.
Contact closed
Contact open
Signal 0
Signal 1
Содержание EWM21xx
Страница 2: ...SOI DT 2007 11 dmm 2 69 599 70 39 88 ...
Страница 57: ...SOI DT 2007 11 dmm 57 69 599 70 39 88 11 3 Diagram WM with UNIVERSAL MOTOR EWM 21xx ...
Страница 59: ...SOI DT 2007 11 dmm 59 69 599 70 39 88 11 4 Diagram WM with THREE PHASE ASYNCHRONOUS MOTOR EWM 25xx ...
Страница 61: ...SOI DT 2007 11 dmm 61 69 599 70 39 88 11 5 Diagram WD with UNIVERSAL MOTOR EWM 21xx ...
Страница 63: ...SOI DT 2007 11 dmm 63 69 599 70 39 88 11 6 Diagram WD with THREE PHASE ASYNCHRONOUS MOTOR EWM 25xx ...