SOI/DT 2005-07 dmm
52/59
599 37 22-15
10.2.3 Operation of alarms during diagnostics
All alarms are enabled during the components diagnostics phase. Moving the selector to pass from one
control phase to the other, the appliance exits the alarm condition and performs the selected phase (if the
alarm does not occur again).
10.3 Notes about some alarms
Configuration alarms
ª
E91
: the error is indicated by the flashing of all the LEDs, E90 is displayed on the display, if featured.
ª
E92
: the error is indicated by the flashing of the LEDs placed over the buttons, E90 is displayed on the
display, if featured.
ª
E93
: the error is indicated by the flashing of the phase/warning LEDs, E90 is displayed on the display, if
featured.
Alarms EB1-EB2-EB3:
in case of problems with the power supply, the machine remains in alarm
condition until the frequency or the power supply voltage returns to the correct values or the appliance
is switched off. The “
B
” alarm family is displayed and it is not possible to enter the diagnostics or to use
“fast alarm display” mode: the complete alarm can be read only when the abnormal situation has
terminated.
Alarms E51- E52:
during the diagnostics test all alarms are displayed: normally, moving the selector to
pass from one control phase to the next, the appliance exits the alarm condition and performs the
selected phase. This does not occur for the E51 alarm (motor power triac short-circuited) and the E52
alarm (no signal from the motor tachimetric generator): the only possibility to exit from the alarm
condition is to switch the appliance off.
10.4 Rapid reading of alarm codes
The last alarm code can be displayed even if the programme selector is not in the tenth position
(diagnostics) or if the appliance is in normal operating mode (e.g. during the execution of the washing
programme):
ª
Press
START/PAUSE
and
SKIP/RESET
buttons simultaneously for at least 2 seconds: the LEDs
switch off and then display the sequence of flashes indicating the alarm.
ª
The alarm sequence is displayed for the time in which the buttons are hold down
ª
The reading system is the same as that indicated in paragraph. 9.2.1
ª
During the time the alarm is displayed, the appliance continues to perform the cycle or, if it is in the
selection phase, it keeps the options previously chosen in memory.
10.5 Cancelling the last alarm
It is good practice to cancel the last alarm, after reading the alarm code to check whether the alarm re-
occurs during the diagnostics control after the repairs t the appliance.
1. Select diagnostics mode and turn the
programme selector to the
tenth
position
(reading of alarm)
2. Press and hold down
START/PAUSE
and
START/RESET
.