Perfect balance
-
Reversing
-
FUCS phase 0
with spin-dry pulse
-
Reversing
-
FUCS phase 1
-
regular spin-dry
Function of the FUCS
“
FUCS
” is an English expression and means “
F
ast
U
nbalanced
C
ontrol
S
ystem”
Function:
The unbalance control includes 4 phases. These phases are of different duration and have different limits
of unbalance. The magnitude of the unbalance is calculated every 300 ms, hereby the magnitude is
compared to the fixed unbalance limits, and then it is decided whether the speed will be increased or
reduced by 2 1/min. FUCS starts at 55 1/min and ends ideally when reaching 115 1/min.
Phase 0:
Phase 0 takes max.60sec. When the unbalance threshold of the first phase is reached, the
appliance performs a spin cycle with 100 1/min for 5 sec followed by a spin cycle pulse of
470 1/min.
Phase 1:
The first phase takes max. 120 sec to obtain the required speed of 115 1/min. If the speed is
not reached after this 120 sec, the spinning cycle will be stopped. The laundry is dispersed
and it is changed to phase 2.
Phase 2:
Phase 2 takes max. 60 sec. Here it is tried to obtain the speed of 115 1/min with various
unbalance limits. If the speed is not reached after 180 sec, the spinning cycle will be stopped
again. The laundry is dispersed and it is changed to phase 3.
Phase 3:
In phase 3, the required speed is reduced to 85 1/min. Within 90 sec, speed should be
reached, the machine then runs a spin-dry cycle at 100 1/min for 5 sec.and a subsequent
spin-dry pulse at 470 1/min, then again starting by phase 1. If the speed is reached, a
reduced spin-dry cycle at 650 1/min is carried out. If the speed is not reached, spin-dry is
skipped.
Содержание EWM 1000 AEG
Страница 31: ... 31 DGS TDS N11 06R B Electrolux 599 51 50 25 EN Circuit Diagram Technicl Specifications ...
Страница 32: ... 32 DGS TDS N11 06R B Electrolux 599 51 50 25 EN Circuit Diagram Wiring Diagram ...
Страница 33: ... 33 DGS TDS N11 06R B Electrolux 599 51 50 25 EN Circuit Diagram Elementary Diagram ...
Страница 40: ... 40 DGS TDS N11 06R B Electrolux 599 51 50 25 EN Changes Date Page changed 24 11 2006 2 3 ...