installation
63
Hard wiring details
1. Remove terminal cover plate from rear panel of
appliance.
2. Fit wires through hole in cover plate and make
connections to terminals.
3. Engage wires into plastic clip. Secure plastic clip with
two long silver screws (supplied in separate bag).
4. Replace cover plate onto rear panel.
Error codes
TECHNICAL SPECIFICATIONS
model
product dimensions
(h x w x d) mm
electrical
connection
min. fuse rating
max. power rating
max. current rating
EVE611SA
597 x 596 x 573
230-240V/50Hz
16A
3.1kW
12.9A
EVE613SA
597 x 596 x 573
230-240V/50Hz
16A
3.1kW
12.9A
EVE614BA
597 x 596 x 573
230-240V/50Hz
16A
3.1kW
12.9A
EVE616BA
597 x 596 x 573
230-240V/50Hz
16A
3.1kW
12.9A
EVEP611SA
597 x 596 x 573
230-240V/50Hz
16A
3.1kW
12.9A
EVEP614BA
597 x 596 x 573
230-240V/50Hz
16A
3.1kW
12.9A
EVEP613SA
597 x 596 x 573
230-240V/50Hz
16A
3.1kW
12.9A
EVEP616BA
597 x 596 x 573
230-240V/50Hz
16A
3.1kW
12.9A
EVEP615SA
597 x 596 x 573
230-240V/50Hz
16A
3.5kW
12.9A
EVEP618BA
597 x 596 x 573
230-240V/50Hz
16A
3.5kW
12.9A
EVE623SA
890 x 596 x 573
230-240V/50Hz
25A
5.3kW
22.1A
EVE633SA
1083 x 596 x 573
230-240V/50Hz
25A
6.2kW
24.2A
error code
description
comment
fix
F01 or 01
Door lock sensor alarm
This relates to a door lock failure which is only
associated with the Pyrolytic product
Check wiring/plugs or replace door lock
F02 or 02
Door lock actuator alarm
F04 or 04
Oven Probe (PT500) out
This relates to the temperature sensing probe
which may be out of tolerance, of range alarm
or have open/short circuit connections
Replace probe
F05 or 05
Oven Probe (PT500) too
high temperature alarm
25
Board Temperature
Sensor (NTC) too high
temperature alarm
This relates to the temperature of the
powerboard and/or the (NTC)
on the powerboard
Cooling fan not working or replace
powerboard
26
Board Temperature
Sensor (NTC) out of
range warning
6
Board Temperature
Sensor (NTC) out of
range alarm
F08 or 08
Communication alarm
This relates to an error in communication
between the powerboard and the IOI
controller. This can occur if the IOI controller is
connected while the powerboard is energised
Reset power. (minimum of 20 sec.) or
check or replace data cable
F09 or 09
Software compatibility
code alarm
This relates to a mismatch between
powerboard firmware version and the IOI
controller firmware version. most likely caused
by an un-programmed powerboard
Replace Powerboard
C1
Telescopic runners fitted
Only applies to Pyrolytic product
Remove both side racks and re-start
pyrolytic cycle
C3
Door open
Only applies to Pyrolytic product
Close door and restart pyrolytic cycle
F03 or 03
EEPROm check sum
alarm
Relates to the controller
Replace Controller
F14 or 14
EEPROm compatibility
code alarm
Relates to the controller
Replace Controller