Cli-
mate
class
Ambient temperature
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
7.2
Location
50 mm
To ensure best performance, if the appli-
ance is positioned below an overhanging
wall unit, the minimum distance between
the top of the cabinet and the wall unit
must be at least 40 mm. Ideally, however,
the appliance should not be positioned
below overhanging wall units.
The ventilation space can be:
• directly above the appliance
• behind and above the top cupboard.
In this case, the space behind the top
cupboard must be at least 50 mm
deep.
7.3
Electrical Connection
CAUTION!
Any electrical work required to in-
stall this appliance should be car-
ried out by a qualified electrician
or competent person.
WARNING!
This appliance must be earthed.
The manufacturer declines any lia-
bility should these safety meas-
ures not be observed.
1
2
3
4
5
The wires in the mains lead are
coloured in accordance with the
following code:
1
Green and Yellow:
Earth
14 www.electrolux.com