electrolux en:v barbecue
leak test procedure/conversion to natural gas 7
Leak test procedure (Universal LPG)
• Ensure all gas valves are in the ‘OFF’ position.
• In a small container, mix a solution of water and
detergent or soap.
• After connection of the hose, turn on the valve at the
gas bottle or mains as appropriate.
• Using a brush apply the solution to the gas connection
points and look for bubbles forming.
• Bubbling will indicate a leak.
• Turn off the valve and re-tighten the joint. Repeat the
leak test.
• If the leak persists, turn off the gas at the isolation
valves and contact a licensed gas fitter to correct.
leak test points
check hose for
signs of abrasions,
cracks or leaks
Conversion to Natural Gas
Preparing the unit for Natural Gas installation.
This barbecue is supplied set up for Universal LPG and is
labelled accordingly. A Natural Gas conversion kit can be
purchased from Electrolux Spare Parts to enable conversion
to Natural Gas use.
NOTE: Conversion of this unit to Natural Gas must be
carried out by a qualified licensed person and a Certificate of
Compliance must be issued to the owner on completion of
the installation and conversion.
The conversion kit consists of:
• Regulator
• Hose with quick connect bayonet fitting one end
• Small plastic bag containing 4 brass injectors
• Natural Gas sticker
Procedure
1. Changing the injectors
• Remove warmer drawer as shown on page 5.
• Remove front service panel by loosening the screws in
3 places. Screws need only be loosened, and not fully
removed.
• Lift service panel from the bottom and swing out
approximately 45 degrees to release the top edge of
the service panel.
loosen 3 screws
on underside
of service panel
swing out to release
service panel