LOCATION OF APPLIANCE
This appliance must not be installed in a bed-sitting room of volume less than 20m³ or in a bathroom, shower
room or garage.
It is essential that there is a minimum clearance of 3mm between the top surface of the appliance and
the inside top of the cabinet. The unit must be fitted into a cabinet conforming to Fig. 1. The following
internal dimensions are particularly important.
Height
575............Minimum
600..........Maximum
Width
560............Minimum
570..........Maximum
Solid Pipe
Depth
560........... Minimum
N/A.........Maximum
Flexible Pipe
Depth
575............Minimum
N/A.........Maximum
NOTE: Where a cupboard door with a handle is situated above the appliance, we recommend a minimum
clearance gap of 5mm between fascia top trim and door. If the appliance is to be installed next to a
cupboards' doors or draws, we recommend that the cabinet heat deflectors, supplied with the appliance be
fitted. These are located behind the front frame and secured in position by the fixing screws (see Installation
Section). This oven unit may be used in a Built-in or a Built-under situation. If the appliance is to be Built-under
a hob, it is recommended that the hob be installed before the oven unit.
L.P.G. cookers MUST NOT be installed below ground level, i.e. in a basement, or aboard any boat, yacht or
other vessel.
35
595
570
540
570 max
560 min
600
2000 recommended
600 max
575 min
560 min
5
600 min
FIG.1
Содержание EOG 6330