The end of the drain pipe
must have an air gap.
Slope pipe downwards
1/4" per foot.
1/2" PVC pipe
1/2" PVC elbow
3/8" ID tubing*
* Install tubing according to pump
manufacturer's instructions.
Condensate pump
Slope pipe downwards
1/4" per foot.
1/2" PVC pipe
The end of the drain pipe
must have an air gap.
Floor drain
MAINTAIN CLEARANCE
DO NOT ADD
ANY VALVES
DO NOT ADD
ANY VALVES
Electrolux
Condensing
Tankless Gas
Water Heater
Electrolux
Condensing
Tankless Gas
Water Heater
Note:
If the drain line becomes clogged or frozen, condensate will back-up into the water heater and a "29"
error code will
flash
on the remote controller, ceasing operation. If this occurs, clear the clog or freeze
so that condensate can freely
flo
w. Be sure to slope the drain pipe, use the appropriate size pipe, allow
the proper clearances, and apply freeze prevention measures (when necessary) to prevent the drain
line from clogging or freezing.
Condensate piping to floor drain
Condensate piping with pump