Natural Gas:
G20 (2H) 20 mbar
14.4 Bypass diameters
BURNER
Ø BYPASS 1/100 mm
Auxiliary
29 / 30
Semi-rapid
32
Rapid
42
Dual
67
Oven
54
Grill
59
14.5 Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POW‐
ER kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Dual
4.5
1.8
150
Rapid
3.0
0.72
119
Semi-rapid
2.0
0.43
96
Auxiliary
1.0
0.35
70
Oven
3.6
1.5
126
Grill
2.5
1.6
111
14.6 Gas burners for LPG G30 28-30 mbar
BURNER
NORMAL POW‐
ER kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Dual
4.5
1.8
104
Rapid
3.0
0.72
88
Semi-rapid
2.0
0.43
71
Auxiliary
1.0
0.35
50
Oven
3.6
1.5
90
Grill
2.5
1.6
80
14.7 Gas connection
The gas pipe in the appliance has two
endings. You can connect the gas supply
to either one of them. The pipe that is not
used must be clogged with the pipe
closer, which added to the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with
the regulation in force. If you use flexible
www.electrolux.com
24