40
Carry out a gas tightness test after
connecting to the gas supply. The
gas bayonet connector must be
fitted in the shaded area indicated in
Fig.2. Take into account that it must
be possible to pull the appliance
forward sufficiently. Ensure the hose
does not become trapped when
pushing the appliance into position.
IMPORTANT: FLEXIBLE TUBING
USED MUST COMPLY WITH
BS.669 CURRENT EDITION.
LPG Flexible connections must be a
type suitable for L.P.G and capable
of operation up to 50 mbar and carry
a red stripe, band or label.
Fitting the stability bracket
It is recommended that if the
appliance is to be installed with a
flexible supply pipe, a stability
bracket be fitted and is available
from your supplier (see Important
Safety Requirements). These
instructions should be read in
conjunction with any leaflet packed
with the stability bracket.
1. Place the appliance in its
intended position and level
appliance.
2. Mark off 250mm from the left
hand side of the appliance as
shown in dimension 'A', Fig
3a.
This is the centre line of the fixing
bracket.
3. Draw a line a 100mm from the
front edge of the feet (see Fig.3a)
and remove appliance from its
position. Mark off dimension 'B'
(see Fig.3a) back from this line
on the centre line of the bracket
to locate the front edge of the
lower bracket.
Fig.3a.
Fig.3b.
48
7m
m
(B
)
250mm
100mm
20mm
(A)
(C)