electrolux
connecting to the gas supply
39
Pressure testing
1. The Rapid injector is used as a
pressure test point.
2. Connect the pressure gauge to the
Rapid injector.
3. Check the supply pressure by
turning the Rapid burner on and one
other hob burner full on and light the
appropriate burner. The pressure
should be either:-
(i)
For Natural Gas 20mbar
(ii)
For LP. Gas. The pressure
must be set to 29 mbar for
use on butane or 37 mbar
for use on propane.
4. Turn off the taps, disconnect the
pressure gauge.
5. Check operation of each hob burner.
Checking the hob
1. Lift the lid. Fit the burner crowns
and caps ensuring that they are
correctly seated. Fit the pan
supports.
2. To light the hob burners push in
and hold the control knob, turn to
large flame symbol (highest setting)
and press the ignition button
immediately. Keep the control
knob depressed for up to 5
seconds, but no longer than 10
seconds. After this time release
the controls. The flame should
remain alight.
3. Turn off the hob and wait 1 minute.
Turn the hob control knob to large
flame symbol (highest setting).
4.
Do not depress or attempt to ignite
the burner. No gas should flow.
Checking the lid shut-off device
1. Lift the lid
2. Turn one hob tap to its full on
position and push the ignition button.
3. Close the lid. There should now be
no gas supply to the hob and the
burner will go out.
4. Turn off the hob and lift the lid. The
gas supply should now be restored
to the hob, when the tap is turned on.
To set the time of day
Please refer to the Timer section.
General note
Instruct the user on how to use the
appliance and its ignition system. Refer
the user to the wording inside this user
manual which gives advice on the safe
operation of the appliance.