(and Optional Electric or Gas Cooktop Combination)

 In cold weather shipping and storage 

conditions, make sure that oven is in final location 
at least three (3) hours before switching on power. 
Switching on power while oven is still cold may damage 
the oven controls.

4. Electrical connection

It is the responsibility and obligation of the consumer to 
contact a qualified installer to assure that the electrical 
installation is adequate and is in conformance with the 
National Electrical Code ANSI/NFPA No. 70-latest edition, 
or with CSA Standard C22.1, Canadian Electrical Code, 
Part 1, and local codes and ordinances.

 

Risk of electrical shock  (Failure to 

heed this warning may result in electrocution or 
other serious injury.) This appliance is equipped 
with copper lead wire. If connection is made to 
aluminum house wiring, use only connectors that 
are approved for joining copper and aluminum wire 
in accordance with the National Electrical Code 
and local code and ordinances. When installing 
connectors having screws which bear directly on 
the steel and/or aluminum flexible conduit, do no 
tighten screws sufficiently to damage the flexible 
conduit. Do not over bend or excessively distort 
flexible conduit to avoid separation of convolutions 
en exposure of internal wires.

DO NOT ground to a gas supply pipe. DO NOT connect 
to electrical power supply until appliance is permanently 
grounded. Connect the ground wire before turning on 
the power.

 (If your appliance is equipped with a 

white neutral conductor.)
This appliance is manufactured with a white neutral 
power supply and a frame connected copper wire. 
The frame is grounded by connection of grounding 
lead to neutral lead at the termination of the 
conduit, if used in USA, in a new branch circuit 
installation (1996 NEC), mobile home, recreational 
vehicles, where local code do not permit grounding 
trough the neutral (white) wire or in Canada, 
disconnect the white and green lead from each 
other and use ground lead to ground unit in 
accordance with local codes, connect neutral lead 
to branch circuit-neutral conductor in usual manner 
see Figure 4. If your appliance is to be connected 
to a 3 wire grounded junction box (US only), 
where local code permit connecting the appliance-
grounding conductor to the neutral (white) see 
Figure 3.

 

NOTE TO ELECTRICIAN:

 The armored cable leads 

supplied with the appliance are UL-recognized for 
connection to larger gauge household wiring. The 
insulation of the leads is rated at temperatures much 
higher than temperature rating of household wiring. The 
current carrying capacity of the conductor is governed by 
the temperature rating of the insulation around the wire, 
rather than the wire gauge alone.

Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire 
(US Only) (see figure 3): 

1.  Disconnect the power supply.
2.  In the junction box:
  connect appliance and power supply cable wires as 

shown in Figure 3.

Electrical Shock Hazard

• Electrical ground is required on this appliance.
• Do not connect to the electrical supply until 

appliance is permanently grounded.

• Disconnect power to the junction box before 

making the electrical connection.

• T h i s   a p p l i a n c e   m u s t   b e   c o n n e c t e d   t o   a 

grounded, metallic, permanent wiring system, 
or a grounding connector should be connected 
to the grounding terminal or wire lead on the 
appliance.

• Do not use a gas supply line for grounding the 

appliance.

Failure to do any of the above could result in a 

fire, personal injury or electrical shock.

Figure 3

3-WIRE GROUNDED JUNCTION BOX

Cable from Power Supply

Black 

Wires

Junction 

Box

Cable from appliance

Ground Wire

(Bare or Green Wire)

White Wire

(Neutral)

U.L.-Listed Conduit 

Connector (or CSA listed)

Red

Wires

White Wire

(Neutral)

Содержание EI27EW35JS

Страница 1: ...event excess heat buildup that may result in heat damage or fire NOTES 1 Base must be capable of supporting 150 pounds 68 kg for 27 models and 200 pounds 90 kg for 30 models 2 Allow at least 21 53 3cm clearance in front of oven for door depth when it is open Suggested distance from floor is 31 78 7cm Minimum required distance is 4 11 4cm 3 Dimension G cutout depth is critical to the proper install...

Страница 2: ... add a 2 5 cm wide wood shim of appropriate height to each side of the opening under the appliance side rails Lifting the unit will allow you to hide the cutout openings showing above the unit The bottom trim of the unit will hide the shims at the bottom 5 For a cutout height H between 49 126 4 cm and 51 130 8 cm you can order a larger bottom trim through your Service Center All dimensions are in ...

Страница 3: ...ght beneath the oven side rails 3 Electrical Requirements This appliance must be supplied with the proper voltage and frequency and connected to an individual properly grounded branch circuit protected by a circuit breaker or fuse To know the circuit breaker or fuse required by your model see the serial plate to find the wattage consumption and refer to table A to get the circuit breaker or fuse a...

Страница 4: ...ranch circuit installation 1996 NEC mobile home recreational vehicles where local code do not permit grounding trough the neutral white wire or in Canada disconnect the white and green lead from each other and use ground lead to ground unit in accordance with local codes connect neutral lead to branch circuit neutral conductor in usual manner see Figure 4 If your appliance is to be connected to a ...

Страница 5: ...te Location Double Wall Oven Serial Plate Location Heavy Weight Hazard Use 2 or more people to move and install wall oven Failure to follow this instruction can result in injury or damage to the unit 5 Cabinet Installation IMPORTANT Do not lift the oven by the door handle Handle On Double Wall Oven Pull the two handles out to lift or carry the appliance When you are done moving the appliance push ...

Страница 6: ...the wall oven and injury to persons A The mounting holes in the side trims may be used as a template to locate the appliance mounting screw holes see figure 6 B Use the two screws supplied to fix the appliance to the cabinet 7 Install the Bottom Trim Place the top of the bottom trim over the side trim tabs on each side of the oven below the oven door and fix it using the 2 screws supplied in the m...

Страница 7: ...lt junction box for built in oven Figure 8 TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT IN OVEN WITH AN ELECTRIC COOKTOP MOUNTED ABOVE Approx 3 7 5 cm Cabinet side filler panels are necessary to isolate the unit from adjoining cabinets Cabinet side filler height should allow for installation of ap proved cooktop models To reduce the risk of personal injury and tipping of the wall ...

Страница 8: ...e oven Refer to your Use Care Guide 3 Verify the operation of the electronic oven controls Bake Verify that this function makes the oven hot 20 seconds after turning oven on open the door and you should feel heat coming from the oven Broil When the oven is set to BROIL the upper element in the oven should become red Convection some models When the oven is set for a convection baking or roasting bo...

Страница 9: ...a cuña de madera de 2 5 cm de ancho para lograr la altura apropiada a cada lado del orificio ubicado PARA SU SEGURIDAD No almanece ni utilice gasolina u otros vapores y líquidos inflamables en la proximidad de este o de cualquier otro artefacto El primer paso para su instalación debe de ser el de medir las dimensiones de la apertura y compararlas con las que se indican en el cuadro de dimensiones ...

Страница 10: ...erior del aparato tapara las calzas que se colocan en la base 5 Para un corte de una altura H entre 49 126 4 cm y 51 130 8 cm una moldura grande inferior puede ser pedido con su representante No quite los separadores de los muros laterales o y de la parte posterior del horno empotrado Estos espaciadores centran el horno en el espacio provisto El horno debe estar centrado para prevenir una concentr...

Страница 11: ... las cuñas de altura apropiada debajo de los rieles laterales del horno 3 Requerimientos Eléctricos Se debe proveer el voltaje y la frecuencia apropiados a este electrodoméstico y conectarse a un circuito individual correctamente puesto a tierra protegido por un interruptor o un fusible Para conocer el interruptor o fusible que requiere su modelo vea la placa serial para encontrar la consumación d...

Страница 12: ...tierra debe conectarse al terminal de puesta a tierra o el alambre conductor en al aparato No utilice el suministro de gas para hacer la puesta a tierra La falta de cualquiera de las instrucciones mencionadas podría resultar en un incendio choque eléctrico o lesiones personales Figura 3 CAJA DE EMPALMES DE 3 ALAMBRES PUESTA A TIERRA Cable desde el suministro de energía Cable de la estufa Alambre d...

Страница 13: ...l orificio del gabinete y hacia la caja de paso mientras se desliza el accesorio hacia adentro 5 Empujar el horno hacia adentro y en contra del gabinete Peligro de Peso Pesado Use 2 personas o más para mover e instalar el horno de pared Si no cumple con esta instrucción puede resultar en lesiones personales o daños al horno de pared Manija En el horno de pared doble Para levantar o transportar la ...

Страница 14: ... pared se incline y ocasione quemaduras graves A Los barrenos en las molduras laterales pueden ser usadas como guía para localizar los tornillos de montado de la unidad figura 6 B Use los dos tornillos proporcionados para colocar la unidad en la cabina Figura 6 7 Instalación de la Guarnición Inferior Colocar la parte superior de la guarnición inferior sobre las lengüetas laterales del horno debajo...

Страница 15: ...rmitir la instala ción de modelos de tapas de cocina aprobados Sólo ciertos modelos de tapas de cocina se pueden instalar sobre ciertos modelos de hornos eléctricos empotrados Las tapas de cocina y los hornos empotrados se mencionan por su número de identificación MFG ID y código de producto ver la planilla que se incluye en el paquete de literatura y las instrucciones de instalación de la cocina ...

Страница 16: ...ncienden y apagan en forma alterna y se enciende el ventilador El ventilador de convección dejará de funcionar cuando se abre la puerta del horno durante el horneado o asado por convección Antes de llamar al servicio Lea la sección Lista de Control de Averías en su Manual del Usuario Esto le podrá ahorrar tiempo y gastos Esta lista incluye ocurrencias comunes que no son el resultado de defectos de...

Страница 17: ...ur les modèles à convection vérifiez la dimension G pour vous assurer qu elle est correcte 4 Si la hauteur de découpage H se situe entre 275 8 70 2 cm et 28 71 8 cm ajoutez une entretoise de bois de 2 5 cm de largeur et de hauteur appropriée de chaque côté de l ouverture sous l appareil L ajout d une entretoise de bois permet de cacher l espace situé au haut de l ouverture de l armoire tandis que ...

Страница 18: ...re 491 8 125 1 cm et 49 126 4 cm ajoutez une entretoise de bois de 2 5 cm de largeur et de hauteur appropriée de chaque côté de l ouverture sous l appareil L ajout d une entretoise de bois permet de cacher l espace situé au haut de l ouverture de l armoire tandis que l espace situé au bas de l ouverture est caché par la moulure décorative de l appareil 5 Si la hauteur de découpage H se situe entre...

Страница 19: ...stré simple ou 49 125 7 cm pour un four encastré double voir la figure 1 ou 2 Placez l entretoise de hauteur appropriée de chaque côté de l ouverture sous l appareil 3 Exigences électriques Ces appareils doivent être branchés à une alimentation possédant la tension et la fréquence appropriées Ils doivent être connectés à un circuit dédié correctement mis à la terre et protégé par un disjoncteur ou...

Страница 20: ...appareil est obligatoire Ne branchez pas l appareil au circuit électrique tant qu il ne sera pas mis à la terre correctement et en permanence Coupez l alimentation à la boîte de jonction avant de faire les raccords électriques Cet appareil doit être connecté à un circuit permanent électrique métallique et mis à la terre ou à un connecteur de mise à la terre qui doit être branché à la borne ou au f...

Страница 21: ...ignement au sujet de votre appareil assurez vous d inclure les numéros de modèle et de série ainsi que le numéro ou lettre de lot de la plaque signalétique de votre four Risque de lourde charge Soyez 2 personnes ou plus pour installer ou déplacer l appareil Des blessures ou des dommages à l appareil peuvent survenir si vous ne suivez pas cette instruction Emplacement de la plaque signalétique des ...

Страница 22: ...le basculement du four et des blessures corporelles A Les vis situées sur les moulures latérales peuvent servir de gabarit voir la figure 6 B Utilisez les deux vis fournies pour fixer l appareil à l armoire Figure 5 Espace d environ 1 3 8 cm 7 Installation de la moulure inférieure Placez le haut de la moulure inférieure par dessus les petites languettes de chaque côté du four encastré sous la port...

Страница 23: ... à l armoire Utilisez un contre plaqué de 1 9 cm d épaisseur monté sur deux solives et à égalité avec le coup de pied La base doit pouvoir suppor ter 150 lbs 68 kg pour les modèles 27 et 200 lbs 90 kg pour les modèles 30 Découpez une ouverture de 4 X 4 10 2cm X 10 2cm à 2 5 cm du côté gauche du plan cher pour la sortie du câble armé de l appareil vers la boîte de jonction Il faut fermer les côtés ...

Страница 24: ...e ventilateur convection situé à l arrière tourne Le ventilateur convection arrête lorsque l on ouvre la porte du four Avant d appeler le service d entretien Réviser la liste de vérifications préventives et les instructions d opération dans votre Manuel d utilisation et d entretien Vous sauverez probablement du temps et de l argent La liste contient les incidents ordinaires ne résultant pas de déf...

Отзывы: