Under-Counter Ice Maker
EI15IM55GS
CANADA
• 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 •
electroluxappliances.ca
EI15IM55GS 12/10
© 2008 Electrolux Major Appliances, NA
Printed in Canada
Under-Counter Ice Maker Specifications
•
Product Weight – 100 Lbs.
•
Voltage Rating –120V/60Hz/15 Amps
•
Connected Load (kW Rating) @120 Volts = 0.48kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
•
Run Amps @120 Volts=4 Amps/Harvest Amps @120 Volts=5.5 Amps
•
Electrical cable supplied.
•
Water supply and electrical power source required.
•
Always consult local and national electric & plumbing codes.
•
Unit is designed for either freestanding or built-in, under-counter
installation.
•
Built-in, under-counter installation does not require additional airspace for
top, sides or rear of unit.
•
Allow 1-1/2" minimum clearance behind unit for electrical, water
supply and drain connections.
•
Front grille MUST remain unobstructed for proper ventilation.
•
Can be installed using gravity drain or optional Drain Pump Kit
(PN# EIMP60).
•
Drain lines must have 5/8" inside diameter, 1" drop per 48" (1/4" per
foot) of run and must not create traps.
•
Floor drain must be large enough to accommodate drainage from
all drains.
•
Recommended water pressure between 30 and 120 pounds
per square inch (psi).
•
Unit MUST be level for proper operation, and positioned on flat surface,
capable of supporting entire weight when fully loaded.
•
Leveling legs supplied to adjust height and level unit.
•
Can be installed outdoors, out of direct sunlight. Do NOT install behind
closed doors.
•
Do not position unit near any heat source or in direct sunlight to ensure
optimum performance. Surrounding air temperature must be at least
50°F but must not exceed 110°F.
•
Unit requires zero clearance when installing flush with cabinet or wall.
•
When installing against cabinet or wall that extends beyond front edge
of unit, 2-7/8" minimum handle clearance required to allow for 90° door
swing, providing sufficient interior access.
(Door is field reversible for
right- or left-hand opening.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.ca or supplied with product
for detailed instructions.
Optional Accessories
•
Drain Pump Kit – (PN# EIMP60).