![Electrolux EHTAROW Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/electrolux/ehtarow/ehtarow_user-manual_92042009.webp)
11
ENGLISH
Amount of detergent during the cycle:
Setting the activation time:
Amount of rinse-aid during the cycle:
Setting the activation time:
Exit from programming mode:
Notes for external dispensers:
-
if
dEt=181
the detergent dispenser
only
operates during
wash pump
operation; terminals
7-9
of the main terminal board are powered at the
same time.
-
if
dEt=182
the detergent dispenser
only
operates during
filling electrovalve
operation for
restoring the boiler level; terminals
7-9
of the main
terminal board are powered at the same time.
-
if
rAi=61
the rinse-aid dispenser
only
operates during
filling electrovalve
operation for
restoring the boiler level; terminals
8-9
of the main
terminal board are powered at the same time.
-
if
rAi=62
the rinse-aid dispenser
only operates
during
wash pump
operation; terminals
8-9
of the
main terminal board are powered at the same time.
For connections, see the wiring diagram.
Example:
Supposing that an external detergent dispenser has
been connected with a tank concentration measuring
sensor, a standard setting could be as follows:
dIn=0
the dispenser is not activated during filling of
the tank.
dEt=181
the dispenser is activated during wash
pump operation and, thanks to the concentration
measured by the conduction sensor, the correct
amount of detergent is dispensed.
Suggestion:
to check the effectiveness of the rinse-
aid, look at freshly washed glasses against the light.
Drops of water remaining on the glass indicate an
insufficient amount while streaks indicate an excess.
Changing the detergent/rinse-aid type.
If changing to a
different detergent/rinse-aid type
(even one by the same manufacturer), you must rinse
the suction and pressure hoses with fresh water before
connecting the new detergent/rinse-aid container.
Otherwise, the mixing of different types of detergent/
rinse-aid will cause crystallisation, which may result in
a breakdown of the dosing pump. Failure to observe
this condition will invalidate the guarantee and product
liability.
3
2
1
-
+
3
2
1
3
2
1
-
+
3
2
1
3
2
1