7
ENGLISH
Install a disconnecting switch with a capacity at
least equal to that given in the technical data table,
a 30mA residual current circuit breaker and an
overcurrent device (magnetothermal cut-out with
manual reset or fuse) between the appliance and
the mains power outlet.
The chosen device must be lockable in the open
position in case of maintenance.
ATTENTION
Do not place the dishwasher near direct heat sour-
ces such as fryers, ovens, hot-plates, etc.
RATING PLATE
The rating plate contains identification and technical
data and is located on the right-hand side panel of the
appliance (Figure 5).
Figure 5
B1
WATER CONNECTION
•
The appliance must be fixed to the ground using
the two clamps supplied (Figure 6).
Figure 6
•
Position the dishwasher and level the appliance by
turning the feet (Figure 5).
•
Accessing the appliance bottom panel.
•
Fit the clamps on feet as shown in supplied techni-
cal sheet.
•
Screw the appliance steadily to the ground using
hole clamps.
•
Connect the appliance water supply pipe “A”
(Figure 4) to the mains, fitting a cut-off cock, the fil-
ter provided and a pressure gauge between the
appliance and the mains (Figure 7).
Figure 7
•
Check that the
dynamic
water supply
pressure
,
measured between the appliance and the main, is
between 50 and 700 kPa
(test while dishwasher
tank or boiler is filling with water).
If the pressure is too high, fit a suitable pres-
sure reducer on the inlet pipe.
Connect the waste outlet pipe “C” (Figure 4) to the
main drain pipe, fitting a trap, or place the outlet pipe
over an S trap set into the floor.
B2
ELECTRICAL CONNECTION
Figure 8
•
Before carrying out the electrical connection, check that
the voltage and frequency on the appliance rating plate
correspond to those of the mains electricity supply.
•
The earth wire at the terminal end must be longer
(max. 20 mm) than the phase wires.
•
Connect the earth wire of the power supply cable to
an efficient earth clamp. The appliance must also
be included in a unipotential system, the connec-
tion being made through the screw “Q” (Figure 4)
marked with the symbol “
”. The unipotential wire
must have a cross section of 10 mm
2
.
B INSTRUCTIONS FOR THE INSTALLER/MAINTENANCE PERSON
Model RT10 ED
PNC 9CGX 531300 05 Ser.N .123000001
AC 400V 3N 50Hz
Power Boiler 16500w
Power Tank 7500w
Power Max 26800w
Made in EEC
Model RT10 ED
PNC 9CGX531300 05
Ser.N .123000001
CAUTION
THE EARTH AND ELECTRICAL CON-
NECTIONS SHOULD BE IN COMPLIANCE
WITH NATIONAL REGULATIONS.
!
AC 400....
1
11
10
9
8
7
6
5
4
3
2
12
!