Electrical connection
The appliance is designed to be connected
to 230 V monophase electricity supply.
The connection must be carried out in
compliance with the laws and regulations in
force.
Before the appliance is connected:
1. check that the main fuse and the
domestic installation can support the
load (see the rating label);
2. check that the power supply is properly
earthed in compliance with the current
rules;
3. check the socket or the double pole
switch used for the electrical connection
can be easily reached with the appliance
built in the forniture unit.
The appliance is supplied with a connection
cable. This has to be provided with a proper
plug, able to support the load marked on the
identification plate. The plug has to be fitted
in a proper socket.
If connecting the appliance directly to the
electric system, it is necessary that you
install a double pole switch between the
appliance and the electricity supply, with a
minimum gap of 3 mm. between the switch
contacts and of a type suitable for the
required load in compliance with the current
rules.
The connection cable has to be placed in
order that, in each part, it cannot reach a
temperature higher than 90°C.
The brown coloured phase cable (fitted in the
terminal block contact marked with "L")
must always be connected to the network
phase.
Replacing the power cable
When replacing the cable, only use
H05V2V2-F (T90) type cables suitable for
the load and working temperature. Also, the
yellow/green earth wire must be about 2 cm
longer than the phase and neutral wires (see
figure).
After connection, test the heating elements
by switching them on for about 3 minutes.
Neutral
Earth (yellow/green)