background image

i

6

CONVERSION PROCEDURE

1. 

Disconnect the appliance from main electrical power supply.

2. Lift off trivets, burner caps, burner crowns, and control knobs.
3. Remove the existing injectors and fit the injectors appropriate for the required gas type as specified in the
table.
4. Fit the Citigas aeration calibrators to the injectors. Aeration calibrators with the large opening must be
fitted to large burner and wok burner. Calibrators with small opening fit medium and small burner.
5. Any faulty or damaged components should be replaced at this point.
6. Adjust the burners to minimum. By turning the screw on the body of the gas control valve (Standard
models) or in the shaft of the gas control valve (Flame safeguard models) Fig.9., adjust the size of the flame
at minimum.
Ensure that the flame does not go out at minimum (Fig. 10).
7. Connect to the main electrical power supply.
8. Check that ignition is satisfactory for all burners.
9. Check proper operation of solid hotplate (if fitted).
10. Stick Citigas data label over LPG information. If the supply cord of this appliance is damaged, it must
only be repIaced by a repair shop appointed by the manufacturer, because special purpose tools are
required. Refer to the local service agency for the correct replacement part. (Part no. 215-2-59)
Any sealing shall be restored after the gas conversion operation.

Table 2.0

LPG (butane)

Citigas

Natural Gas

*Appliance

Operating

27.5 mbar

10.0 mbar

20.0 mbar

Pressure (p)

Injector

Rating - grams/hr.

Injector

Rating - kW

Injector

Rating - kW

Size

(kW)

Size

Size

Wok

1.00

290 (4.0)

4.00

4.0

1.50

4.2

Large

0.90

230 (3.2)

2.82

2.9

1.19

3.1

Medium

0.70

130 (1.8)

2.10

2.1

0.96

1.9

Small

0.55

90 (1.2)

1.42

1.1

0.70

1.0

Fig. 9

* Adjust pressure with appliance operating at approximately 50% of maximum kW

Содержание EHG678 Series

Страница 1: ...i I N F O I N S T R U C T I O N M A N U A L B U I L T I N H O B Models EHG678 EHG978 EHM684 EHM984 EHG977 EHG983 EHG682 EHG982 Denotes colour W White X Stainless Steel ...

Страница 2: ...or additional ventilation for example opening of a window or more effective ventilation for example increasing the level of mechanical ventilation where present CONTROLS AND OPERATION Each burner is controlled by a valve which is activated by a control knob that diagrammatically shows high to low Fig 1A Where a solid hotplate is fitted it is controlled by an infinite control knob which gives a ran...

Страница 3: ...mum surface appearance stainless steel must be kept clean by regularly using the following cleaning procedures thus ensuring good performance and long service life Wash with warm soapy water and rinse with clean water For an enhanced appearance wipe the surface with light oil eg sewing machine then wipe the surface dry with a soft clean lintless cloth being sure to follow the polish or brushing li...

Страница 4: ...e of a combustible surface must not exceed 50 C above ambient temperature 3 PULL DOWN CLAMPS four supplied are supplied in a parts bag with their corresponding screws four supplied To assemble attach the 4 clamps to each corner of the burner box via the screws provided When placing the appliance in the cutout swing the clamps parallel with the box to avoid interference with the cutout 4 SAFETY BAR...

Страница 5: ...rth connection This must be connected to a domestic earth The domestic power outlet should be located within 600mm of the flexible cord connection point ref Fig 4 Whenever thesocket or the installation does not have available an earthing connection such connection must be provided according to the local standards APPLIANCE DIMENSIONS MODEL A B C Square Models 600 535 45 Rectangular Models 860 510 ...

Страница 6: ...while awaiting service The customer should be advised that in the event of a fault the Electrolux local Service Organisation or the retailer from whom the appliance was purchased should be contacted 5 When satisfied that the unit is operating correctly turn off and instruct the customer on correct operation as outlined in this booklet Ask the customer to operate the controls to ensure that the cor...

Страница 7: ... the flame does not go out at minimum Fig 10 7 Connect to the main electrical power supply 8 Check that ignition is satisfactory for all burners 9 Check proper operation of solid hotplate if fitted 10 Stick Citigas data label over LPG information If the supply cord of this appliance is damaged it must only be repIaced by a repair shop appointed by the manufacturer because special purpose tools are...

Страница 8: ...i 7 P No 342 1 487 ECN 04A076G MANUFACTURER Electrolux Home Products Pty Ltd P O Box 21 Prospect South Australia 5082 ...

Отзывы: