CONVERSION PROCEDURE
1.
Disconnect the appliance from main electrical power supply.
2. Lift off trivets, burner caps, burner crowns, and control knobs.
3. Remove the existing injectors and fit the injectors appropriate for the required gas type as specified in the
table.
4. Fit the Citigas aeration calibrators to the injectors. Aeration calibrators with the large opening must be
fitted to large burner and wok burner. Calibrators with small opening fit medium and small burner.
5. Any faulty or damaged components should be replaced at this point.
6. Adjust the burners to minimum. By turning the screw on the body of the gas control valve (Standard
models) or in the shaft of the gas control valve (Flame safeguard models) Fig.9., adjust the size of the flame
at minimum.
Ensure that the flame does not go out at minimum (Fig. 10).
7. Connect to the main electrical power supply.
8. Check that ignition is satisfactory for all burners.
9. Check proper operation of solid hotplate (if fitted).
10. Stick Citigas data label over LPG information. If the supply cord of this appliance is damaged, it must
only be repIaced by a repair shop appointed by the manufacturer, because special purpose tools are
required. Refer to the local service agency for the correct replacement part. (Part no. 215-2-59)
Any sealing shall be restored after the gas conversion operation.
Table 2.0
LPG (butane)
Citigas
Natural Gas
*Appliance
Operating
27.5 mbar
10.0 mbar
20.0 mbar
Pressure (p)
Injector
Rating - grams/hr.
Injector
Rating - kW
Injector
Rating - kW
Size
(kW)
Size
Size
Wok
1.00
290 (4.0)
4.00
4.0
1.50
4.2
Large
0.90
230 (3.2)
2.82
2.9
1.19
3.1
Medium
0.70
130 (1.8)
2.10
2.1
0.96
1.9
Small
0.55
90 (1.2)
1.42
1.1
0.70
1.0
Fig. 9
* Adjust pressure with appliance operating at approximately 50% of maximum kW