background image

10

FITTING THE GAS HOB

WITHOUT A COOKER HOOD ABOVE

FITTING THE GAS HOB

WITH A COOKER HOOD ABOVE

700 mm

400 mm

100 mm

400 mm

50 mm

55 mm

50 mm

650 mm

400 mm

400 mm

100 mm

50 mm

50 mm

55 mm

600 mm

FO 0812

FO 0813

Important safety requirements

This hob must be installed in accordance with the Gas

Safety (Installation and Use) Regulations (Current Edition)

and the IEE Wiring Regulations (Current Edition).

Detailed recommendations are contained in the following

British Standards Codes Of Practice: B.S. 6172/ B.S.

5440, Part 2 and B.S. 6891 Current Editions.

The hob should not be installed in a bed sitting room

with a volume of less than 20 m

3

. If it is installed in a

room of volume less than 5 m

3

 an air vent of effective

area of 110 cm

2

 is required. If it is installed in a room of

volume between 5 m

3

 and 10 m

3

 an air vent of effective

area of 50 cm

2

 is required, while if the volume exceeds

11 m

3

 no air vent is required.

However, if the room has a door which opens directly to

the outside no air vent is required even if the volume is

between 5 m

and 11 m

3

.

If there are other fuel burning appliances in the same

room,  B.S.  5440  Part  2  Current  Edition,  should  be

consulted to determine the requisite air vent requirements.

Location

The hob may be located in a kitchen, a kitchen/diner or

bed sitting room, but not in a bathroom, shower room or

garage.

Before making the cut out in the worktop ensure that the

edges of the hob that are to be near either a side or rear

wall have a minimum distance of 55 mm. between the

edge of the hob and the wall.

The minimum distance combustible material can be fitted

above the hob is 400 mm. If it is fitted below 400 mm. a

space of 50 mm. must be allowed from the edges of the

hob.

The minimum distance combustible material can be fitted

directly above the hob is 700 mm.

A minimum distance of 100 mm. must be left between

the side edges of the hob and any adjacent cabinets or

walls.

Installation

IMPORTANT

This  hob  must  be  installed  by 

qualified

personnel

 to the relevant British Standards.

Any gas installation must be carried out by a

registered CORGI installer.

The manufacturer will not accept liability, should

the above instructions or any of the other safety

instructions  incorporated  in  this  book  be

ignored.

WHEN THE HOB IS FIRST INSTALLED

Once the hob has been installed, it is important

to remove any protective materials, which were

put on in the factory.

On  the  end  of  the  shaft,  which  includes  the  GJ  1/2"

threaded elbow, adjustment is fixed so that the washer

is  fitted  between  the  components  as  shown  in  the

diagram. Screw the parts together without using excessive

force.

Содержание EHG 678

Страница 1: ...GB Gas hobs INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance EHG 678 35670 2702 ...

Страница 2: ...b is intended for domestic cooking only It is not designed for commercial or industrial purposes l When in use a gas cooking appliance will produce heat and moisture in the room in which it has been installed Ensure there is a continuous air supply keeping air vents in good condition or installing a cooker hood with a venting hose l When using the hob for a long period of time the ventilation shou...

Страница 3: ...g 5 Service and Spare Parts 6 Guarantee Conditions 6 Engineers technical data 9 Installation 10 Building In 11 Electrical connections 12 Wiring Diagram 13 Fault Finding 13 Commissioning 15 Conversion from Natural Gas to LPG 15 Description of the Hob 1 Hob Top 2 Rapid Burner 3 Semi rapid Burners 4 Auxiliary Burner 5 Control Panel 6 Control knobs 1 2 3 4 6 5 ...

Страница 4: ...ny maintenance or cleaning can be carried out you must DISCONNECT the hob from the electricity supply The hob is best cleaned whilst it is still warm as spillage can be removed more easily than if it is left to cool The Hob Top Regularly wipe over the hob top using a soft cloth well wrungoutinwarmwatertowhichalittlewashingupliquid has been added Avoid the use of the following household detergent a...

Страница 5: ... Please note that it will be necessary to provide proof of purchase for any in guarantee service calls In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown Service and Spare Parts When you contact the Service Centre they will need the following information 1 Your name address and post c...

Страница 6: ...liance which is improperly installed or calls to appliance outside the United Kingdom Appliances found to be in use within a commercial or similar environment plus those which are the subject of rental agreements Products of Electrolux manufacture which are not marketed by Electrolux European Guarantee If you should move to another country within Europe then your guarantee moves with you to your n...

Страница 7: ...an Ridge Road Sheffield S9 1GB NORTH WEST BIRKENHEAD 1 Kelvin Park M11 Dock Road Birkenhead L41 1LT CARLISLE Unit 7 M10 James Street Workshops James Street Carlisle Cumbria CA2 5AH ISLE OF MAN South Quay Ind M64 Estate Douglas Isle of Man IM1 5AT LIVERPOOL Unit 1 M15 Honeys Green Precinct Honeys Green Lane Liverpool L12 9JH MANCHESTER Unit B M09 Central Industrial Estate St Marks Street Bolton BL3...

Страница 8: ...eld London EN3 7BB GRAVESEND Unit B4 M57 Imperial Business Estate Gravesend Kent DA11 0DL HARPENDEN Unit 4 M46 Riverside Estate Coldharbour Lane Harpenden AL5 4UN LETCHWORTH 16 17 Woodsite Ind M50 Est Works Road Letchworth Herts SG6 1LA LONDON 2 4 Royal Lane M76 Yiewsley West Drayton Middlesex UB7 8DL MAIDENHEAD Reform Road M60 Maidenhead Berkshire SL6 8BY MOLESEY 10 Island Farm M61 Avenue West Mo...

Страница 9: ...r semi rapid Heat Input 2 0 kW 6824 BTU HR Front Left Burner rapid Heat Input 3 0 kW Natural Gas 10236 BTU HR 2 8 kW LPG 9554 BTU HR Burner Dia Tap By pass 1 100 mm Auxiliary 28 Semi rapid 32 Rapid 40 Aerationadjustmentnone NATURAL GAS 20 mbar TYPE OF GAS Characteristics LPG GAS 28 30 37 mbar 1 100 mm 1 100 mm VALUE 49 92 MJ Kg VALUE 37 78 MJ m 3 Ws 50 7 MJ m 3 Rear Right Burner semi rapid Heat In...

Страница 10: ... requirements Location The hob may be located in a kitchen a kitchen diner or bed sitting room but not in a bathroom shower room or garage Before making the cut out in the worktop ensure that the edges of the hob that are to be near either a side or rear wall have a minimum distance of 55 mm between the edge of the hob and the wall The minimum distance combustible material can be fitted above the ...

Страница 11: ...ow easy access if technical assistance is needed The space behind the kitchen unit b can be used for connections Rectangular cut out size for hob A End of shaft with nut B Washer C Elbow It is important to install the elbow correctly with the shoulder on the end of the thread fitted to the hob connecting pipe Failure to ensure the correct assembly will cause leakage of gas FO 0814 Gas Connection C...

Страница 12: ...the fuse a 3ampASTAapproved BS 1362 fuse must be used Should the plug need to be replaced for any reason the wires in the mains lead are coloured in accordance with the following code Green and Yellow Earth Blue Neutral Brown Live Connect the green and yellow earth wire to the terminal in the plug which is marked with the letter E or the earth symbol or coloured green and yellow Connect the blue n...

Страница 13: ...ess than infinity there is a fault NOTE Should it be found that the fuse has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trace the faulty component It is possible that a fault could occur as a result of local burning arcing but no fault could be found under test However a detailed visual inspection should reveal evide...

Страница 14: ...Light burner manually Check gas supply at burner Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check for breaks in the insula...

Страница 15: ...ssure reading should be nominally 20mbar and must be between 17 mbar and 25mbar Turn off the burner supplies F F Conversion from Natural Gas to LPG It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted The gas rate is adjusted to suit Method Ensure that the gas taps are in the ...

Страница 16: ...Group The world s No 1 choice The Electrolux Group is the world s largest producer of powered appliances for kitchen cleaning and outdoor use More than 55 Group products such as refrigerators cookers washing machines vacuum cleaners chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world 09 09 ...