INSTALLING THE COOKER HOOD
electrolux 23
EN
Extraction
The charcoal
fi
lter is not required in this
mode and should be removed.
Ducting
The ducting used must be Ø150mm
(6ins), or Ø125mm (5ins) in diameter.
If possible duct through the wall
immediately above the hood body.
For the best performance use the
shortest possible duct run and the
minimum number of bends.
Where
fl
exible ducting is
fi
tted it should
not be turned through very tight bends
as this may impair the performance of
the hood.
It is recommenmded a maximum length
of 3 metres, to be installed, to be reduced
1 metre for each 90
o
bend installed in the
ducting run.
If the distance is greater than 3 metres
the ef
fi
cency of the hood could be
impaired.
The diameter of the ducting spigot on the
top of the hood body item 1 is Ø150mm
(6”).
When using Ø125mm (5”) ducting it
will be necessary to install the ducting
adapter item
9
to the Ø150mm (6”)
outlet on the top of the hood body and
the Ø120mm to 125mm ducting collar
item
10
(supplied).
If the room where the cooker hood
is to be used contains a fuel burning
appliance such as a central heating
boiler, then its
fl
ue must be of the
room sealed or balanced
fl
ue type.
If other types of
fl
ue or appliances are
fi
tted ensure that there is an adequa-
te supply of air to the room.
The cooker ducting (extraction mode)
must never be connected to central
heating
fl
ues, radiators or water
heaters etc.
9
ø 150
ø 125
10
Содержание EFC90950
Страница 1: ...USER MANUAL EFC90950 ...
Страница 2: ...We were thinking of you when we made this product ...
Страница 5: ...YOUR APPLIANCE AND OPERATING INSTRUCTIONS electrolux 5 EN YOUR APPLIANCE 650 min ...
Страница 25: ...electrolux 25 ...
Страница 26: ...electrolux 26 ...
Страница 27: ......
Страница 28: ...www electrolux com 436003743_01 070323 ...